NPD_110429101034.xml
9.6 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
<witsml:drillReports version="1.4.0.0" xmlns:witsml="http://www.witsml.org/schemas/1series" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.witsml.org/schemas/1series http://www.npd.no/schema/DDRS/1series/WITSML_drillReport_profiled_schema_phase2.xsd">
<witsml:drillReport>
<witsml:nameWell>25/8-C-23</witsml:nameWell>
<witsml:nameWellbore>25/08-C-23 B</witsml:nameWellbore>
<witsml:name>25/8-C-23</witsml:name>
<witsml:dTimStart>2011-04-28T06:00:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-29T06:00:00.001Z</witsml:dTimEnd>
<witsml:versionKind>normal</witsml:versionKind>
<witsml:createDate>2011-04-29T08:10:00.001Z</witsml:createDate>
<witsml:wellAlias>
<witsml:name>25/8-C-23</witsml:name>
<witsml:namingSystem>NPD code</witsml:namingSystem>
</witsml:wellAlias>
<witsml:wellboreAlias>
<witsml:name>25/8-C-23 B</witsml:name>
<witsml:namingSystem>NPD code</witsml:namingSystem>
</witsml:wellboreAlias>
<witsml:wellboreAlias>
<witsml:name>6480</witsml:name>
<witsml:namingSystem>NPD number</witsml:namingSystem>
</witsml:wellboreAlias>
<witsml:wellDatum>
<witsml:name>Kelly Bushing</witsml:name>
<witsml:code>KB</witsml:code>
<witsml:elevation uom="m">32</witsml:elevation>
</witsml:wellDatum>
<witsml:wellDatum>
<witsml:name>Sea Level</witsml:name>
<witsml:code>SL</witsml:code>
<witsml:elevation uom="m">32</witsml:elevation>
</witsml:wellDatum>
<witsml:wellboreInfo>
<witsml:dTimSpud>2011-01-24T06:00:00.001Z</witsml:dTimSpud>
<witsml:operator>Esso Norway</witsml:operator>
<witsml:drillContractor>KCA Deutag</witsml:drillContractor>
<witsml:rigAlias>
<witsml:name>Ringhorne</witsml:name>
<witsml:namingSystem>NPD Name</witsml:namingSystem>
</witsml:rigAlias>
<witsml:rigAlias>
<witsml:name>280849</witsml:name>
<witsml:namingSystem>NPD Code</witsml:namingSystem>
</witsml:rigAlias>
</witsml:wellboreInfo>
<witsml:statusInfo>
<witsml:dTim>2011-04-28T06:00:00.001Z</witsml:dTim>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:presTestType>formation integrity test</witsml:presTestType>
<witsml:distDrill uom="m">0</witsml:distDrill>
<witsml:elevKelly uom="m">60.2999992370605</witsml:elevKelly>
<witsml:sum24Hr>Tripped out of hole with running tool from 1000 m MD to surface while laying down HWDP on pipe deck. Laid down Quantum packer running tool. Washed / jetted BOP and wellhead. Tested BOPs. </witsml:sum24Hr>
<witsml:forecast24Hr>PU and RIH with cleanout assembly BHA. RIH with casing cleanout assembly to 5 m above Quantum packer.</witsml:forecast24Hr>
</witsml:statusInfo>
<witsml:activity>
<witsml:dTimStart>2011-04-28T06:00:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-28T09:30:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>completion -- completion string</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>POOH with lower completion running string from 1000 m MD to 737 m MD. Lay down range 2 HWDP while POOH with lower completion running string, stopping periodically to rearrange HWDP on Pipe Deck. Performed successful kick drill, duration: 55 seconds. </witsml:comments>
</witsml:activity>
<witsml:activity>
<witsml:dTimStart>2011-04-28T09:30:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-28T09:45:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>interruption -- other</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>BDOS common alarm went off 2 times within 1 hour. Electrician reset alarm, work continued.</witsml:comments>
</witsml:activity>
<witsml:activity>
<witsml:dTimStart>2011-04-28T09:45:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-28T18:00:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>completion -- completion string</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>POOH with lower completion running string from 737 m MD to 128 m MD. Lay down range 2 HWDP while POOH with lower completion running string, stopping periodically to rearrange HWDP on Pipe Deck. Changed teflon on gripper activator for knuckle boom crane on Pipe Deck. Removed remote operated slips. Installed hydraulic operated Weatherford slips with integrated safety clamp (less than 10 tons on string). Continued to POOH with running tool from 128 m MD to surface. Break out and lay down Quantum packer running tool. </witsml:comments>
</witsml:activity>
<witsml:activity>
<witsml:dTimStart>2011-04-28T18:00:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-28T20:00:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>completion -- completion string</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>Clean and clear rig floor. Make up wear bushing running tool and RIH. Retrieved wear bushing. POOH and lay down running tool and bushing. Make up and RIH with wash/jet assembly. </witsml:comments>
</witsml:activity>
<witsml:activity>
<witsml:dTimStart>2011-04-28T20:00:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-28T20:30:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>completion -- circulating conditioning</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>Washed/jetted well head and BOP area. Pumped 1800 lpm, 14 bar. Rotated 10 rpm. </witsml:comments>
</witsml:activity>
<witsml:activity>
<witsml:dTimStart>2011-04-28T20:30:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-28T20:45:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>completion -- completion string</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>POOH with wash/jet assembly. Lay down same.</witsml:comments>
</witsml:activity>
<witsml:activity>
<witsml:dTimStart>2011-04-28T20:45:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-29T04:00:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>completion -- bop/wellhead equipment</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>Made up BOP test plug. Changed seal. Drained riser. RIH with test plug assembly. Performed line test to 15 bar for 5 minutes and 241 bar for 10 minutes, good test. Tested lower pipe rams and upper pipe rams (with 5 1/2" DP) to 15 bar for 5 minutes and 241 bar for 10 minutes, good test. Test annular to 15 bar for 5 minutes and 241 bar for 10 minutes, good test. Test shear rams, good test. POOH and lay down test plug assembly. </witsml:comments>
</witsml:activity>
<witsml:activity>
<witsml:dTimStart>2011-04-29T04:00:00.001Z</witsml:dTimStart>
<witsml:dTimEnd>2011-04-29T06:00:00.001Z</witsml:dTimEnd>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:phase>fixed</witsml:phase>
<witsml:proprietaryCode>completion -- completion string</witsml:proprietaryCode>
<witsml:state>ok</witsml:state>
<witsml:stateDetailActivity>success</witsml:stateDetailActivity>
<witsml:comments>Pick up and RIH with wear bushing, set same. Lay down running tool. Clean and clear rig floor. Prepare to pick up / make up casing cleanout assembly.</witsml:comments>
</witsml:activity>
<witsml:equipFailureInfo>
<witsml:dTim>2011-04-28T09:30:00.001Z</witsml:dTim>
<witsml:md uom="m">6414</witsml:md>
<witsml:tvd uom="m">1800.09082865924</witsml:tvd>
<witsml:equipClass>drill floor -- draw works</witsml:equipClass>
<witsml:eTimMissProduction uom="min">15</witsml:eTimMissProduction>
<witsml:dTimRepair>2011-04-28T09:45:00.001Z</witsml:dTimRepair>
<witsml:description>BDOS common alarm went off 2 times within 1 hour. Electrician reset alarm, work continued.</witsml:description>
</witsml:equipFailureInfo>