Showing
5 changed files
with
173 additions
and
5 deletions
... | @@ -3572,16 +3572,18 @@ mpr-tables:WellProductionFlows | ... | @@ -3572,16 +3572,18 @@ mpr-tables:WellProductionFlows |
3572 | [ sp:varName "productFlowInMonthMaterial"^^xsd:string | 3572 | [ sp:varName "productFlowInMonthMaterial"^^xsd:string |
3573 | ] | 3573 | ] |
3574 | ] [ sp:object | 3574 | ] [ sp:object |
3575 | - [ sp:varName "productFlowInMonthMaterial"^^xsd:string | 3575 | + [ sp:varName "productionFlowMixedPart"^^xsd:string |
3576 | ] ; | 3576 | ] ; |
3577 | sp:predicate <http://www.reportinghub.no/ep/schema/core#temporalPartOf> ; | 3577 | sp:predicate <http://www.reportinghub.no/ep/schema/core#temporalPartOf> ; |
3578 | sp:subject | 3578 | sp:subject |
3579 | - [ sp:varName "quantityofmaterialinaspecifiedstate"^^xsd:string | 3579 | + [ sp:varName "partOfProductionFlowMixedPart"^^xsd:string |
3580 | ] | 3580 | ] |
3581 | - ] [ sp:object <http://www.reportinghub.no/ep/schema/material#QuantityOfMaterial> ; | 3581 | + ] [ sp:object |
3582 | - sp:predicate rdf:type ; | ||
3583 | - sp:subject | ||
3584 | [ sp:varName "quantityofmaterialinaspecifiedstate"^^xsd:string | 3582 | [ sp:varName "quantityofmaterialinaspecifiedstate"^^xsd:string |
3583 | + ] ; | ||
3584 | + sp:predicate <http://www.reportinghub.no/ep/schema/flow#materialThatFlows> ; | ||
3585 | + sp:subject | ||
3586 | + [ sp:varName "partOfProductionFlowMixedPart"^^xsd:string | ||
3585 | ] | 3587 | ] |
3586 | ] [ sp:object <http://www.reportinghub.no/ep/schema/material#QuantityOfMaterialInASpecifiedState> ; | 3588 | ] [ sp:object <http://www.reportinghub.no/ep/schema/material#QuantityOfMaterialInASpecifiedState> ; |
3587 | sp:predicate rdf:type ; | 3589 | sp:predicate rdf:type ; | ... | ... |
1 | +<!DOCTYPE html> | ||
2 | +<html> | ||
3 | + <head> | ||
4 | + <META http-equiv="Content-Type" content="text/html; charset=utf-8"> | ||
5 | + <link href="http://spinrdf.org/rhlib/ddr.css" rel="stylesheet" type="text/css"> | ||
6 | + <title>Monthly Production Report (government)</title> | ||
7 | + </head> | ||
8 | + <body> | ||
9 | + <h1>Monthly Government Report : ÅSGARD Field, Month Ending 2012-01-31</h1> | ||
10 | + <h2>Report title : ÅSGARD</h2> | ||
11 | + <h2>Report version : 2.0</h2> | ||
12 | + <h2>Report Status : final version of a report</h2> | ||
13 | + <h2>Submitted by : ÅSGARD</h2> | ||
14 | + <div> | ||
15 | + <hr> | ||
16 | + <h2>Production Saleable</h2> | ||
17 | + <table class="ddrTable"> | ||
18 | + <tr class="ddrTR"> | ||
19 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
20 | + </tr> | ||
21 | + <tr class="ddrTR"> | ||
22 | + <td class="ddrTD">ÅSGARD</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">35514558.02 kg</td><td class="ddrTD">217477.72 m3</td><td class="ddrTD">762.18 kg/m3</td><td class="ddrTD">saleable flow</td><td class="ddrTD">net product flow</td> | ||
23 | + </tr> | ||
24 | + </table> | ||
25 | + <br> | ||
26 | + </div> | ||
27 | + </body> | ||
28 | +</html> |
This diff could not be displayed because it is too large.
1 | +<!DOCTYPE html> | ||
2 | +<html> | ||
3 | + <head> | ||
4 | + <META http-equiv="Content-Type" content="text/html; charset=utf-8"> | ||
5 | + <link href="http://spinrdf.org/rhlib/ddr.css" rel="stylesheet" type="text/css"> | ||
6 | + <title>Monthly Production Report (government)</title> | ||
7 | + </head> | ||
8 | + <body> | ||
9 | + <h1>Monthly Government Report : TRYM Field, Month Ending 2012-02-29</h1> | ||
10 | + <h2>Report title : TRYM</h2> | ||
11 | + <h2>Report version : 1.0</h2> | ||
12 | + <h2>Report Status : final version of a report</h2> | ||
13 | + <h2>Submitted by : TRYM</h2> | ||
14 | + <div> | ||
15 | + <hr> | ||
16 | + <h2>Gas Sales</h2> | ||
17 | + <table class="ddrTable"> | ||
18 | + <tr class="ddrTR"> | ||
19 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Seller</th><th class="ddrTH" style="text-align: center">Seller Volume</th><th class="ddrTH" style="text-align: center">Seller Work</th><th class="ddrTH" style="text-align: center">Buyer</th><th class="ddrTH" style="text-align: center">Buyer Volume</th><th class="ddrTH" style="text-align: center">Buyer Work</th> | ||
20 | + </tr> | ||
21 | + <tr class="ddrTR"> | ||
22 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1257.49 m3</td><td class="ddrTD">57378.27 MJ</td><td class="ddrTD">DONG DK</td><td class="ddrTD">166.78 m3</td><td class="ddrTD">49208.46 MJ</td> | ||
23 | + </tr> | ||
24 | + <tr class="ddrTR"> | ||
25 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1257.49 m3</td><td class="ddrTD">57378.27 MJ</td><td class="ddrTD">EXXONMOBIL GAS DE</td><td class="ddrTD">445.86 m3</td><td class="ddrTD">18743.95 MJ</td> | ||
26 | + </tr> | ||
27 | + <tr class="ddrTR"> | ||
28 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1257.49 m3</td><td class="ddrTD">57378.27 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">644.85 m3</td><td class="ddrTD">57939.04 MJ</td> | ||
29 | + </tr> | ||
30 | + <tr class="ddrTR"> | ||
31 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1570.53 m3</td><td class="ddrTD">20380.92 MJ</td><td class="ddrTD">DONG DK</td><td class="ddrTD">1570.53 m3</td><td class="ddrTD">23986.6 MJ</td> | ||
32 | + </tr> | ||
33 | + <tr class="ddrTR"> | ||
34 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">273.64 m3</td><td class="ddrTD">69275.09 MJ</td><td class="ddrTD">EXXONMOBIL GAS DE</td><td class="ddrTD">178.85 m3</td><td class="ddrTD">70561.21 MJ</td> | ||
35 | + </tr> | ||
36 | + <tr class="ddrTR"> | ||
37 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">273.64 m3</td><td class="ddrTD">69275.09 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">94.79 m3</td><td class="ddrTD">20148.59 MJ</td> | ||
38 | + </tr> | ||
39 | + </table> | ||
40 | + <br> | ||
41 | + </div> | ||
42 | + <div> | ||
43 | + <hr> | ||
44 | + <h2>Well Production</h2> | ||
45 | + <table class="ddrTable"> | ||
46 | + <tr class="ddrTR"> | ||
47 | + <th class="ddrTH" style="text-align: center">Wellbore</th><th class="ddrTH" style="text-align: center">Status</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Day</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
48 | + </tr> | ||
49 | + <tr class="ddrTR"> | ||
50 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">684.52 m3</td><td class="ddrTD">17</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
51 | + </tr> | ||
52 | + <tr class="ddrTR"> | ||
53 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">755.89 m3</td><td class="ddrTD">17</td><td class="ddrTD">allocated flow</td><td class="ddrTD">net product flow</td> | ||
54 | + </tr> | ||
55 | + <tr class="ddrTR"> | ||
56 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1957.3 m3</td><td class="ddrTD">17</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
57 | + </tr> | ||
58 | + <tr class="ddrTR"> | ||
59 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">114.61 m3</td><td class="ddrTD">10</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
60 | + </tr> | ||
61 | + <tr class="ddrTR"> | ||
62 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1744.5 m3</td><td class="ddrTD">10</td><td class="ddrTD">allocated flow</td><td class="ddrTD">net product flow</td> | ||
63 | + </tr> | ||
64 | + <tr class="ddrTR"> | ||
65 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">800.44 m3</td><td class="ddrTD">10</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
66 | + </tr> | ||
67 | + </table> | ||
68 | + <br> | ||
69 | + </div> | ||
70 | + <div> | ||
71 | + <hr> | ||
72 | + <h2>Cargo Information</h2> | ||
73 | + <table class="ddrTable"> | ||
74 | + <tr class="ddrTR"> | ||
75 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Cargo Number</th><th class="ddrTH" style="text-align: center">Cargo Batch</th><th class="ddrTH" style="text-align: center">Bill of Lading</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Shipper</th><th class="ddrTH" style="text-align: center">Destination</th><th class="ddrTH" style="text-align: center">Country</th><th class="ddrTH" style="text-align: center">Owner</th><th class="ddrTH" style="text-align: center">Share</th> | ||
76 | + </tr> | ||
77 | + <tr class="ddrTR"> | ||
78 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">395/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-02-06</td><td class="ddrTD">1683.82 m3</td><td class="ddrTD">110.85 kg</td><td class="ddrTD">705.75 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
79 | + </tr> | ||
80 | + <tr class="ddrTR"> | ||
81 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">396/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-02-11</td><td class="ddrTD">782.72 m3</td><td class="ddrTD">267.5 kg</td><td class="ddrTD">770.49 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
82 | + </tr> | ||
83 | + <tr class="ddrTR"> | ||
84 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">397/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-02-16</td><td class="ddrTD">1270.75 m3</td><td class="ddrTD">146.43 kg</td><td class="ddrTD">790.83 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
85 | + </tr> | ||
86 | + <tr class="ddrTR"> | ||
87 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">398/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-02-19</td><td class="ddrTD">979.89 m3</td><td class="ddrTD">744.24 kg</td><td class="ddrTD">795.49 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
88 | + </tr> | ||
89 | + </table> | ||
90 | + <br> | ||
91 | + </div> | ||
92 | + <div> | ||
93 | + <hr> | ||
94 | + <h2>Production Saleable</h2> | ||
95 | + <table class="ddrTable"> | ||
96 | + <tr class="ddrTR"> | ||
97 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
98 | + </tr> | ||
99 | + <tr class="ddrTR"> | ||
100 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">614.09 kg</td><td class="ddrTD">1094.62 m3</td><td class="ddrTD">788.93 kg/m3</td><td class="ddrTD">saleable flow</td><td class="ddrTD">net product flow</td> | ||
101 | + </tr> | ||
102 | + </table> | ||
103 | + <br> | ||
104 | + </div> | ||
105 | + <div> | ||
106 | + <hr> | ||
107 | + <h2>Production Inventory</h2> | ||
108 | + <table class="ddrTable"> | ||
109 | + <tr class="ddrTR"> | ||
110 | + <th class="ddrTH" style="text-align: center">Inventory Name</th><th class="ddrTH" style="text-align: center">Inventory Type</th><th class="ddrTH" style="text-align: center">Product</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th> | ||
111 | + </tr> | ||
112 | + <tr class="ddrTR"> | ||
113 | + <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">519.72 m3</td><td class="ddrTD">756.03 kg/m3</td> | ||
114 | + </tr> | ||
115 | + <tr class="ddrTR"> | ||
116 | + <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">519.72 m3</td><td class="ddrTD">756.03 kg/m3</td> | ||
117 | + </tr> | ||
118 | + </table> | ||
119 | + <br> | ||
120 | + </div> | ||
121 | + <div> | ||
122 | + <hr> | ||
123 | + <h2>Production Inventory Ownership</h2> | ||
124 | + <table class="ddrTable"> | ||
125 | + <tr class="ddrTR"> | ||
126 | + <th class="ddrTH" style="text-align: center">Inventory Name</th><th class="ddrTH" style="text-align: center">Inventory Type</th><th class="ddrTH" style="text-align: center">Product</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Owner</th> | ||
127 | + </tr> | ||
128 | + <tr class="ddrTR"> | ||
129 | + <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">85.86 m3</td><td class="ddrTD">DONG E&P Norge AS</td> | ||
130 | + </tr> | ||
131 | + <tr class="ddrTR"> | ||
132 | + <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">433.86 m3</td><td class="ddrTD">Bayerngas Norge AS</td> | ||
133 | + </tr> | ||
134 | + </table> | ||
135 | + <br> | ||
136 | + </div> | ||
137 | + </body> | ||
138 | +</html> |
This diff could not be displayed because it is too large.
-
Please register or login to post a comment