Showing
2 changed files
with
686 additions
and
818 deletions
1 | -<!DOCTYPE html> | ||
2 | -<html> | ||
3 | - <head> | ||
4 | - <META http-equiv="Content-Type" content="text/html; charset=utf-8"> | ||
5 | - <link href="http://spinrdf.org/rhlib/ddr.css" rel="stylesheet" type="text/css"> | ||
6 | - <title>Monthly Production Report (Partner)</title> | ||
7 | - </head> | ||
8 | - <body> | ||
9 | - <h1>Monthly Partner Report : Field, Month Ending 2012-03-31</h1> | ||
10 | - <h2>Report title : TRYM all</h2> | ||
11 | - <h2>Report Status : final version of a report</h2> | ||
12 | - <h2>Submitted by : </h2> | ||
13 | - <div> | ||
14 | - <hr> | ||
15 | - <h2>Gas Sales</h2> | ||
16 | - <table class="ddrTable"> | ||
17 | - <tr class="ddrTR"> | ||
18 | - <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Seller</th><th class="ddrTH" style="text-align: center">Seller Volume</th><th class="ddrTH" style="text-align: center">Seller Work</th><th class="ddrTH" style="text-align: center">Buyer</th><th class="ddrTH" style="text-align: center">Buyer Volume</th><th class="ddrTH" style="text-align: center">Buyer Work</th> | ||
19 | - </tr> | ||
20 | - <tr class="ddrTR"> | ||
21 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">10180.48 m3</td><td class="ddrTD">37782.02 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">10180.48 m3</td><td class="ddrTD">40154.03 MJ</td> | ||
22 | - </tr> | ||
23 | - <tr class="ddrTR"> | ||
24 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">2608.94 m3</td><td class="ddrTD">18559.96 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">2608.94 m3</td><td class="ddrTD">32543.13 MJ</td> | ||
25 | - </tr> | ||
26 | - <tr class="ddrTR"> | ||
27 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">3472.17 m3</td><td class="ddrTD">26569.73 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">3472.17 m3</td><td class="ddrTD">13599.3 MJ</td> | ||
28 | - </tr> | ||
29 | - <tr class="ddrTR"> | ||
30 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">7385.39 m3</td><td class="ddrTD">20325.48 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">7385.39 m3</td><td class="ddrTD">20741.86 MJ</td> | ||
31 | - </tr> | ||
32 | - <tr class="ddrTR"> | ||
33 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">8304.68 m3</td><td class="ddrTD">36799.5 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">8304.68 m3</td><td class="ddrTD">44283.93 MJ</td> | ||
34 | - </tr> | ||
35 | - <tr class="ddrTR"> | ||
36 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">838.1 m3</td><td class="ddrTD">27737.9 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">838.1 m3</td><td class="ddrTD">43482.79 MJ</td> | ||
37 | - </tr> | ||
38 | - <tr class="ddrTR"> | ||
39 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1275.84 m3</td><td class="ddrTD">31523.32 MJ</td><td class="ddrTD">DONG DK</td><td class="ddrTD">1275.84 m3</td><td class="ddrTD">51881.56 MJ</td> | ||
40 | - </tr> | ||
41 | - <tr class="ddrTR"> | ||
42 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1762.18 m3</td><td class="ddrTD">45081.26 MJ</td><td class="ddrTD">EXXONMOBIL GAS DE</td><td class="ddrTD">1762.18 m3</td><td class="ddrTD">19063.31 MJ</td> | ||
43 | - </tr> | ||
44 | - <tr class="ddrTR"> | ||
45 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1817.82 m3</td><td class="ddrTD">57725.93 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">1817.82 m3</td><td class="ddrTD">48800.09 MJ</td> | ||
46 | - </tr> | ||
47 | - <tr class="ddrTR"> | ||
48 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">322.12 m3</td><td class="ddrTD">37594.68 MJ</td><td class="ddrTD">EXXONMOBIL GAS DE</td><td class="ddrTD">35.59 m3</td><td class="ddrTD">42643.44 MJ</td> | ||
49 | - </tr> | ||
50 | - <tr class="ddrTR"> | ||
51 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">322.12 m3</td><td class="ddrTD">37594.68 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">251.65 m3</td><td class="ddrTD">24235.67 MJ</td> | ||
52 | - </tr> | ||
53 | - <tr class="ddrTR"> | ||
54 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">322.12 m3</td><td class="ddrTD">37594.68 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">34.88 m3</td><td class="ddrTD">77124.51 MJ</td> | ||
55 | - </tr> | ||
56 | - <tr class="ddrTR"> | ||
57 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">383.98 m3</td><td class="ddrTD">9585.57 MJ</td><td class="ddrTD">EXXONMOBIL GAS DE</td><td class="ddrTD">146.02 m3</td><td class="ddrTD">41743.01 MJ</td> | ||
58 | - </tr> | ||
59 | - <tr class="ddrTR"> | ||
60 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">383.98 m3</td><td class="ddrTD">9585.57 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">237.96 m3</td><td class="ddrTD">12550.84 MJ</td> | ||
61 | - </tr> | ||
62 | - <tr class="ddrTR"> | ||
63 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">881.51 m3</td><td class="ddrTD">16518.42 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">437.53 m3</td><td class="ddrTD">34759.74 MJ</td> | ||
64 | - </tr> | ||
65 | - <tr class="ddrTR"> | ||
66 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">881.51 m3</td><td class="ddrTD">16518.42 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">443.98 m3</td><td class="ddrTD">40055 MJ</td> | ||
67 | - </tr> | ||
68 | - <tr class="ddrTR"> | ||
69 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">894.85 m3</td><td class="ddrTD">35415.22 MJ</td><td class="ddrTD">EXXONMOBIL GAS DE</td><td class="ddrTD">12.53 m3</td><td class="ddrTD">23132.1 MJ</td> | ||
70 | - </tr> | ||
71 | - <tr class="ddrTR"> | ||
72 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">894.85 m3</td><td class="ddrTD">35415.22 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">882.32 m3</td><td class="ddrTD">72635.18 MJ</td> | ||
73 | - </tr> | ||
74 | - <tr class="ddrTR"> | ||
75 | - <td class="ddrTD">TRYM</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1063.17 m3</td><td class="ddrTD">39751.49 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">1063.17 m3</td><td class="ddrTD">74152.75 MJ</td> | ||
76 | - </tr> | ||
77 | - <tr class="ddrTR"> | ||
78 | - <td class="ddrTD">TRYM</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">6089.16 m3</td><td class="ddrTD">66668.95 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">6089.16 m3</td><td class="ddrTD">70730.22 MJ</td> | ||
79 | - </tr> | ||
80 | - </table> | ||
81 | - <br> | ||
82 | - </div> | ||
83 | - <div> | ||
84 | - <hr> | ||
85 | - <h2>Well Production</h2> | ||
86 | - <table class="ddrTable"> | ||
87 | - <tr class="ddrTR"> | ||
88 | - <th class="ddrTH" style="text-align: center">Wellbore</th><th class="ddrTH" style="text-align: center">Status</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Day</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
89 | - </tr> | ||
90 | - <tr class="ddrTR"> | ||
91 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1077 m3</td><td class="ddrTD">7</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
92 | - </tr> | ||
93 | - <tr class="ddrTR"> | ||
94 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">176.81 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
95 | - </tr> | ||
96 | - <tr class="ddrTR"> | ||
97 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">566.98 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
98 | - </tr> | ||
99 | - <tr class="ddrTR"> | ||
100 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1234.44 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
101 | - </tr> | ||
102 | - <tr class="ddrTR"> | ||
103 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1155.52 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
104 | - </tr> | ||
105 | - <tr class="ddrTR"> | ||
106 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1077 m3</td><td class="ddrTD">7</td><td class="ddrTD">allocated flow</td><td class="ddrTD">net product flow</td> | ||
107 | - </tr> | ||
108 | - <tr class="ddrTR"> | ||
109 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">889.39 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
110 | - </tr> | ||
111 | - <tr class="ddrTR"> | ||
112 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1382.79 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
113 | - </tr> | ||
114 | - <tr class="ddrTR"> | ||
115 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1044.97 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
116 | - </tr> | ||
117 | - <tr class="ddrTR"> | ||
118 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1088.73 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
119 | - </tr> | ||
120 | - <tr class="ddrTR"> | ||
121 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1077 m3</td><td class="ddrTD">7</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
122 | - </tr> | ||
123 | - <tr class="ddrTR"> | ||
124 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1517.42 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
125 | - </tr> | ||
126 | - <tr class="ddrTR"> | ||
127 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1094.5 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
128 | - </tr> | ||
129 | - <tr class="ddrTR"> | ||
130 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">768.7 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
131 | - </tr> | ||
132 | - <tr class="ddrTR"> | ||
133 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1486.07 m3</td><td class="ddrTD">7</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
134 | - </tr> | ||
135 | - <tr class="ddrTR"> | ||
136 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">805.02 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
137 | - </tr> | ||
138 | - <tr class="ddrTR"> | ||
139 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1221.76 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
140 | - </tr> | ||
141 | - <tr class="ddrTR"> | ||
142 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1150.54 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
143 | - </tr> | ||
144 | - <tr class="ddrTR"> | ||
145 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1612.81 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
146 | - </tr> | ||
147 | - <tr class="ddrTR"> | ||
148 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">809 m3</td><td class="ddrTD">17</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
149 | - </tr> | ||
150 | - <tr class="ddrTR"> | ||
151 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">192.96 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
152 | - </tr> | ||
153 | - <tr class="ddrTR"> | ||
154 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">324.41 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
155 | - </tr> | ||
156 | - <tr class="ddrTR"> | ||
157 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1529.49 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
158 | - </tr> | ||
159 | - <tr class="ddrTR"> | ||
160 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1094.08 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
161 | - </tr> | ||
162 | - <tr class="ddrTR"> | ||
163 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">809 m3</td><td class="ddrTD">17</td><td class="ddrTD">allocated flow</td><td class="ddrTD">net product flow</td> | ||
164 | - </tr> | ||
165 | - <tr class="ddrTR"> | ||
166 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">37.24 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
167 | - </tr> | ||
168 | - <tr class="ddrTR"> | ||
169 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">573.37 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
170 | - </tr> | ||
171 | - <tr class="ddrTR"> | ||
172 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1934.04 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
173 | - </tr> | ||
174 | - <tr class="ddrTR"> | ||
175 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1171.3 m3</td><td class="ddrTD">17</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
176 | - </tr> | ||
177 | - <tr class="ddrTR"> | ||
178 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">809 m3</td><td class="ddrTD">17</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
179 | - </tr> | ||
180 | - </table> | ||
181 | - <br> | ||
182 | - </div> | ||
183 | - <div> | ||
184 | - <hr> | ||
185 | - <h2>Cargo Information</h2> | ||
186 | - <table class="ddrTable"> | ||
187 | - <tr class="ddrTR"> | ||
188 | - <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Cargo Number</th><th class="ddrTH" style="text-align: center">Cargo Batch</th><th class="ddrTH" style="text-align: center">Bill of Lading</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Shipper</th><th class="ddrTH" style="text-align: center">Destination</th><th class="ddrTH" style="text-align: center">Country</th><th class="ddrTH" style="text-align: center">Owner</th><th class="ddrTH" style="text-align: center">Share</th> | ||
189 | - </tr> | ||
190 | - <tr class="ddrTR"> | ||
191 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">301/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1200.23 m3</td><td class="ddrTD">38 kg</td><td class="ddrTD">722.98 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
192 | - </tr> | ||
193 | - <tr class="ddrTR"> | ||
194 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">301/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1200.23 m3</td><td class="ddrTD">38 kg</td><td class="ddrTD">722.98 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
195 | - </tr> | ||
196 | - <tr class="ddrTR"> | ||
197 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">302/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">1015.27 m3</td><td class="ddrTD">21.43 kg</td><td class="ddrTD">736.48 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
198 | - </tr> | ||
199 | - <tr class="ddrTR"> | ||
200 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">302/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">1015.27 m3</td><td class="ddrTD">21.43 kg</td><td class="ddrTD">736.48 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
201 | - </tr> | ||
202 | - <tr class="ddrTR"> | ||
203 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">303/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">1475.49 m3</td><td class="ddrTD">146.7 kg</td><td class="ddrTD">703.15 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
204 | - </tr> | ||
205 | - <tr class="ddrTR"> | ||
206 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">303/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">1475.49 m3</td><td class="ddrTD">146.7 kg</td><td class="ddrTD">703.15 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
207 | - </tr> | ||
208 | - <tr class="ddrTR"> | ||
209 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">304/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-20</td><td class="ddrTD">74.19 m3</td><td class="ddrTD">56.7 kg</td><td class="ddrTD">761.87 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
210 | - </tr> | ||
211 | - <tr class="ddrTR"> | ||
212 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">304/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-20</td><td class="ddrTD">74.19 m3</td><td class="ddrTD">56.7 kg</td><td class="ddrTD">761.87 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
213 | - </tr> | ||
214 | - <tr class="ddrTR"> | ||
215 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">306/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1239.24 m3</td><td class="ddrTD">531.55 kg</td><td class="ddrTD">748.06 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
216 | - </tr> | ||
217 | - <tr class="ddrTR"> | ||
218 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">306/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1239.24 m3</td><td class="ddrTD">531.55 kg</td><td class="ddrTD">748.06 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
219 | - </tr> | ||
220 | - <tr class="ddrTR"> | ||
221 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">307/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">727.88 m3</td><td class="ddrTD">102.11 kg</td><td class="ddrTD">710.81 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
222 | - </tr> | ||
223 | - <tr class="ddrTR"> | ||
224 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">307/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">727.88 m3</td><td class="ddrTD">102.11 kg</td><td class="ddrTD">710.81 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
225 | - </tr> | ||
226 | - <tr class="ddrTR"> | ||
227 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">308/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1712.35 m3</td><td class="ddrTD">918.08 kg</td><td class="ddrTD">730.6 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
228 | - </tr> | ||
229 | - <tr class="ddrTR"> | ||
230 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">308/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1712.35 m3</td><td class="ddrTD">918.08 kg</td><td class="ddrTD">730.6 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
231 | - </tr> | ||
232 | - <tr class="ddrTR"> | ||
233 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">309/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">618.88 m3</td><td class="ddrTD">275.79 kg</td><td class="ddrTD">754.86 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
234 | - </tr> | ||
235 | - <tr class="ddrTR"> | ||
236 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">309/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">618.88 m3</td><td class="ddrTD">275.79 kg</td><td class="ddrTD">754.86 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
237 | - </tr> | ||
238 | - <tr class="ddrTR"> | ||
239 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">310/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-21</td><td class="ddrTD">272.99 m3</td><td class="ddrTD">819.18 kg</td><td class="ddrTD">781.98 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
240 | - </tr> | ||
241 | - <tr class="ddrTR"> | ||
242 | - <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">310/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-21</td><td class="ddrTD">272.99 m3</td><td class="ddrTD">819.18 kg</td><td class="ddrTD">781.98 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
243 | - </tr> | ||
244 | - <tr class="ddrTR"> | ||
245 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">301/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1200.23 m3</td><td class="ddrTD">38 kg</td><td class="ddrTD">722.98 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
246 | - </tr> | ||
247 | - <tr class="ddrTR"> | ||
248 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">302/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">1015.27 m3</td><td class="ddrTD">21.43 kg</td><td class="ddrTD">736.48 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
249 | - </tr> | ||
250 | - <tr class="ddrTR"> | ||
251 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">303/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">1475.49 m3</td><td class="ddrTD">146.7 kg</td><td class="ddrTD">703.15 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
252 | - </tr> | ||
253 | - <tr class="ddrTR"> | ||
254 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">304/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-20</td><td class="ddrTD">74.19 m3</td><td class="ddrTD">56.7 kg</td><td class="ddrTD">761.87 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
255 | - </tr> | ||
256 | - <tr class="ddrTR"> | ||
257 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">306/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1239.24 m3</td><td class="ddrTD">531.55 kg</td><td class="ddrTD">748.06 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
258 | - </tr> | ||
259 | - <tr class="ddrTR"> | ||
260 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">307/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">727.88 m3</td><td class="ddrTD">102.11 kg</td><td class="ddrTD">710.81 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
261 | - </tr> | ||
262 | - <tr class="ddrTR"> | ||
263 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">308/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1712.35 m3</td><td class="ddrTD">918.08 kg</td><td class="ddrTD">730.6 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
264 | - </tr> | ||
265 | - <tr class="ddrTR"> | ||
266 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">309/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">618.88 m3</td><td class="ddrTD">275.79 kg</td><td class="ddrTD">754.86 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
267 | - </tr> | ||
268 | - <tr class="ddrTR"> | ||
269 | - <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">310/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-21</td><td class="ddrTD">272.99 m3</td><td class="ddrTD">819.18 kg</td><td class="ddrTD">781.98 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
270 | - </tr> | ||
271 | - <tr class="ddrTR"> | ||
272 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">301/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1200.23 m3</td><td class="ddrTD">38 kg</td><td class="ddrTD">722.98 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
273 | - </tr> | ||
274 | - <tr class="ddrTR"> | ||
275 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">301/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1200.23 m3</td><td class="ddrTD">38 kg</td><td class="ddrTD">722.98 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
276 | - </tr> | ||
277 | - <tr class="ddrTR"> | ||
278 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">302/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">1015.27 m3</td><td class="ddrTD">21.43 kg</td><td class="ddrTD">736.48 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
279 | - </tr> | ||
280 | - <tr class="ddrTR"> | ||
281 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">302/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">1015.27 m3</td><td class="ddrTD">21.43 kg</td><td class="ddrTD">736.48 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
282 | - </tr> | ||
283 | - <tr class="ddrTR"> | ||
284 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">303/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">1475.49 m3</td><td class="ddrTD">146.7 kg</td><td class="ddrTD">703.15 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
285 | - </tr> | ||
286 | - <tr class="ddrTR"> | ||
287 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">303/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">1475.49 m3</td><td class="ddrTD">146.7 kg</td><td class="ddrTD">703.15 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
288 | - </tr> | ||
289 | - <tr class="ddrTR"> | ||
290 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">304/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-20</td><td class="ddrTD">74.19 m3</td><td class="ddrTD">56.7 kg</td><td class="ddrTD">761.87 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
291 | - </tr> | ||
292 | - <tr class="ddrTR"> | ||
293 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">304/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-20</td><td class="ddrTD">74.19 m3</td><td class="ddrTD">56.7 kg</td><td class="ddrTD">761.87 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
294 | - </tr> | ||
295 | - <tr class="ddrTR"> | ||
296 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">306/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1239.24 m3</td><td class="ddrTD">531.55 kg</td><td class="ddrTD">748.06 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
297 | - </tr> | ||
298 | - <tr class="ddrTR"> | ||
299 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">306/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">1239.24 m3</td><td class="ddrTD">531.55 kg</td><td class="ddrTD">748.06 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
300 | - </tr> | ||
301 | - <tr class="ddrTR"> | ||
302 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">307/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">727.88 m3</td><td class="ddrTD">102.11 kg</td><td class="ddrTD">710.81 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
303 | - </tr> | ||
304 | - <tr class="ddrTR"> | ||
305 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">307/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">727.88 m3</td><td class="ddrTD">102.11 kg</td><td class="ddrTD">710.81 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
306 | - </tr> | ||
307 | - <tr class="ddrTR"> | ||
308 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">308/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1712.35 m3</td><td class="ddrTD">918.08 kg</td><td class="ddrTD">730.6 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
309 | - </tr> | ||
310 | - <tr class="ddrTR"> | ||
311 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">308/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1712.35 m3</td><td class="ddrTD">918.08 kg</td><td class="ddrTD">730.6 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
312 | - </tr> | ||
313 | - <tr class="ddrTR"> | ||
314 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">309/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">618.88 m3</td><td class="ddrTD">275.79 kg</td><td class="ddrTD">754.86 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
315 | - </tr> | ||
316 | - <tr class="ddrTR"> | ||
317 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">309/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">618.88 m3</td><td class="ddrTD">275.79 kg</td><td class="ddrTD">754.86 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Kalundborg</td><td class="ddrTD">DENMARK</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
318 | - </tr> | ||
319 | - <tr class="ddrTR"> | ||
320 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">310/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-21</td><td class="ddrTD">272.99 m3</td><td class="ddrTD">819.18 kg</td><td class="ddrTD">781.98 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
321 | - </tr> | ||
322 | - <tr class="ddrTR"> | ||
323 | - <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">310/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-21</td><td class="ddrTD">272.99 m3</td><td class="ddrTD">819.18 kg</td><td class="ddrTD">781.98 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
324 | - </tr> | ||
325 | - </table> | ||
326 | - <br> | ||
327 | - </div> | ||
328 | - <div> | ||
329 | - <hr> | ||
330 | - <h2>Production Saleable</h2> | ||
331 | - <table class="ddrTable"> | ||
332 | - <tr class="ddrTR"> | ||
333 | - <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
334 | - </tr> | ||
335 | - <tr class="ddrTR"> | ||
336 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">837.88 kg</td><td class="ddrTD">1591.43 m3</td><td class="ddrTD">758.84 kg/m3</td><td class="ddrTD">saleable flow</td><td class="ddrTD">net product flow</td> | ||
337 | - </tr> | ||
338 | - </table> | ||
339 | - <br> | ||
340 | - </div> | ||
341 | - <div> | ||
342 | - <hr> | ||
343 | - <h2>Production</h2> | ||
344 | - <table class="ddrTable"> | ||
345 | - <tr class="ddrTR"> | ||
346 | - <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Flow subtype</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
347 | - </tr> | ||
348 | - <tr class="ddrTR"> | ||
349 | - <td class="ddrTD">TRYM</td><td class="ddrTD">consumption flow - flare</td><td class="ddrTD">gas</td><td class="ddrTD">36260600.47 kg</td><td class="ddrTD">386796.88 m3</td><td class="ddrTD">0.52 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
350 | - </tr> | ||
351 | - <tr class="ddrTR"> | ||
352 | - <td class="ddrTD">TRYM</td><td class="ddrTD">consumption flow - fuel</td><td class="ddrTD">diesel</td><td class="ddrTD"></td><td class="ddrTD">38.68 litre</td><td class="ddrTD"></td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
353 | - </tr> | ||
354 | - <tr class="ddrTR"> | ||
355 | - <td class="ddrTD">TRYM</td><td class="ddrTD">consumption flow - fuel</td><td class="ddrTD">gas</td><td class="ddrTD">38969942.32 kg</td><td class="ddrTD">410251.4 m3</td><td class="ddrTD">0.58 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
356 | - </tr> | ||
357 | - <tr class="ddrTR"> | ||
358 | - <td class="ddrTD">TRYM</td><td class="ddrTD">export</td><td class="ddrTD">oil gross</td><td class="ddrTD">79852251.06 kg</td><td class="ddrTD">136687 m3</td><td class="ddrTD">761.83 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD">gross product flow</td> | ||
359 | - </tr> | ||
360 | - <tr class="ddrTR"> | ||
361 | - <td class="ddrTD">TRYM</td><td class="ddrTD">injection flow</td><td class="ddrTD">gas</td><td class="ddrTD">34510489.65 kg</td><td class="ddrTD">420352 m3</td><td class="ddrTD">0.8 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
362 | - </tr> | ||
363 | - <tr class="ddrTR"> | ||
364 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD"></td><td class="ddrTD">74482982.84 kg</td><td class="ddrTD">121653 m3</td><td class="ddrTD">752.41 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
365 | - </tr> | ||
366 | - <tr class="ddrTR"> | ||
367 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD"></td><td class="ddrTD">73487585.66 kg</td><td class="ddrTD">121653 m3</td><td class="ddrTD">764.96 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
368 | - </tr> | ||
369 | - <tr class="ddrTR"> | ||
370 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">859.13 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
371 | - </tr> | ||
372 | - <tr class="ddrTR"> | ||
373 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">128.08 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
374 | - </tr> | ||
375 | - <tr class="ddrTR"> | ||
376 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1671.91 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
377 | - </tr> | ||
378 | - <tr class="ddrTR"> | ||
379 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">733.31 kg</td><td class="ddrTD">1472.05 m3</td><td class="ddrTD">781.63 kg/m3</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
380 | - </tr> | ||
381 | - <tr class="ddrTR"> | ||
382 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">272.7 kg</td><td class="ddrTD">1652 m3</td><td class="ddrTD">762.39 kg/m3</td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
383 | - </tr> | ||
384 | - <tr class="ddrTR"> | ||
385 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">870.76 kg</td><td class="ddrTD">989 m3</td><td class="ddrTD">780.6 kg/m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
386 | - </tr> | ||
387 | - <tr class="ddrTR"> | ||
388 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">361.55 kg</td><td class="ddrTD">1010 m3</td><td class="ddrTD">785.38 kg/m3</td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
389 | - </tr> | ||
390 | - <tr class="ddrTR"> | ||
391 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">859.56 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
392 | - </tr> | ||
393 | - <tr class="ddrTR"> | ||
394 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1600.37 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
395 | - </tr> | ||
396 | - <tr class="ddrTR"> | ||
397 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1045.95 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
398 | - </tr> | ||
399 | - <tr class="ddrTR"> | ||
400 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">171.18 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
401 | - </tr> | ||
402 | - <tr class="ddrTR"> | ||
403 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1.32 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
404 | - </tr> | ||
405 | - <tr class="ddrTR"> | ||
406 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1222.61 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
407 | - </tr> | ||
408 | - <tr class="ddrTR"> | ||
409 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">286.41 kg</td><td class="ddrTD">1623.07 m3</td><td class="ddrTD">720.63 kg/m3</td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
410 | - </tr> | ||
411 | - <tr class="ddrTR"> | ||
412 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1210.34 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
413 | - </tr> | ||
414 | - <tr class="ddrTR"> | ||
415 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1244.17 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
416 | - </tr> | ||
417 | - <tr class="ddrTR"> | ||
418 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1779.14 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
419 | - </tr> | ||
420 | - <tr class="ddrTR"> | ||
421 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">900.01 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
422 | - </tr> | ||
423 | - <tr class="ddrTR"> | ||
424 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">766.8 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
425 | - </tr> | ||
426 | - <tr class="ddrTR"> | ||
427 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1416.95 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
428 | - </tr> | ||
429 | - <tr class="ddrTR"> | ||
430 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">727.67 kg</td><td class="ddrTD">643 m3</td><td class="ddrTD">752.05 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
431 | - </tr> | ||
432 | - <tr class="ddrTR"> | ||
433 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1049.18 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
434 | - </tr> | ||
435 | - <tr class="ddrTR"> | ||
436 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1115.13 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
437 | - </tr> | ||
438 | - <tr class="ddrTR"> | ||
439 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">522.59 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
440 | - </tr> | ||
441 | - <tr class="ddrTR"> | ||
442 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">146.16 kg</td><td class="ddrTD">1697.55 m3</td><td class="ddrTD">0.64 kg/m3</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
443 | - </tr> | ||
444 | - <tr class="ddrTR"> | ||
445 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">991.05 kg</td><td class="ddrTD">1652 m3</td><td class="ddrTD">0.67 kg/m3</td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
446 | - </tr> | ||
447 | - <tr class="ddrTR"> | ||
448 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">215.71 kg</td><td class="ddrTD">989 m3</td><td class="ddrTD">0.62 kg/m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
449 | - </tr> | ||
450 | - <tr class="ddrTR"> | ||
451 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">782.77 kg</td><td class="ddrTD">1010 m3</td><td class="ddrTD">0.96 kg/m3</td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
452 | - </tr> | ||
453 | - <tr class="ddrTR"> | ||
454 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">175.59 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
455 | - </tr> | ||
456 | - <tr class="ddrTR"> | ||
457 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1430.39 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
458 | - </tr> | ||
459 | - <tr class="ddrTR"> | ||
460 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">91.88 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
461 | - </tr> | ||
462 | - <tr class="ddrTR"> | ||
463 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1709.54 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
464 | - </tr> | ||
465 | - <tr class="ddrTR"> | ||
466 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">754.34 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
467 | - </tr> | ||
468 | - <tr class="ddrTR"> | ||
469 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">575.45 kg</td><td class="ddrTD">1.89 m3</td><td class="ddrTD">0.94 kg/m3</td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
470 | - </tr> | ||
471 | - <tr class="ddrTR"> | ||
472 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">654.03 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
473 | - </tr> | ||
474 | - <tr class="ddrTR"> | ||
475 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">85.69 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
476 | - </tr> | ||
477 | - <tr class="ddrTR"> | ||
478 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1419.41 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
479 | - </tr> | ||
480 | - <tr class="ddrTR"> | ||
481 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1128.52 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
482 | - </tr> | ||
483 | - <tr class="ddrTR"> | ||
484 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">977.16 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
485 | - </tr> | ||
486 | - <tr class="ddrTR"> | ||
487 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">230.11 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
488 | - </tr> | ||
489 | - <tr class="ddrTR"> | ||
490 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1827.87 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
491 | - </tr> | ||
492 | - <tr class="ddrTR"> | ||
493 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">969.08 kg</td><td class="ddrTD">643 m3</td><td class="ddrTD">0.82 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
494 | - </tr> | ||
495 | - <tr class="ddrTR"> | ||
496 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">286.08 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
497 | - </tr> | ||
498 | - <tr class="ddrTR"> | ||
499 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">167.4 kg</td><td class="ddrTD">266.75 m3</td><td class="ddrTD">729.1 kg/m3</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
500 | - </tr> | ||
501 | - <tr class="ddrTR"> | ||
502 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">574.42 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
503 | - </tr> | ||
504 | - <tr class="ddrTR"> | ||
505 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">639.24 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
506 | - </tr> | ||
507 | - <tr class="ddrTR"> | ||
508 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">98.8 kg</td><td class="ddrTD">1652 m3</td><td class="ddrTD">701.86 kg/m3</td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
509 | - </tr> | ||
510 | - <tr class="ddrTR"> | ||
511 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">77396490.68 kg</td><td class="ddrTD">121653 m3</td><td class="ddrTD">771.88 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
512 | - </tr> | ||
513 | - <tr class="ddrTR"> | ||
514 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">41.1 kg</td><td class="ddrTD">989 m3</td><td class="ddrTD">792.55 kg/m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
515 | - </tr> | ||
516 | - <tr class="ddrTR"> | ||
517 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">548.36 kg</td><td class="ddrTD">1010 m3</td><td class="ddrTD">779.06 kg/m3</td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
518 | - </tr> | ||
519 | - <tr class="ddrTR"> | ||
520 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1611.68 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
521 | - </tr> | ||
522 | - <tr class="ddrTR"> | ||
523 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1742.52 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
524 | - </tr> | ||
525 | - <tr class="ddrTR"> | ||
526 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1548.49 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
527 | - </tr> | ||
528 | - <tr class="ddrTR"> | ||
529 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">50.66 kg</td><td class="ddrTD">1702.09 m3</td><td class="ddrTD">732.09 kg/m3</td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
530 | - </tr> | ||
531 | - <tr class="ddrTR"> | ||
532 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1432.53 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
533 | - </tr> | ||
534 | - <tr class="ddrTR"> | ||
535 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1875.48 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
536 | - </tr> | ||
537 | - <tr class="ddrTR"> | ||
538 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1725.22 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
539 | - </tr> | ||
540 | - <tr class="ddrTR"> | ||
541 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1232.49 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
542 | - </tr> | ||
543 | - <tr class="ddrTR"> | ||
544 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">386.72 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
545 | - </tr> | ||
546 | - <tr class="ddrTR"> | ||
547 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1866.65 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
548 | - </tr> | ||
549 | - <tr class="ddrTR"> | ||
550 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">659.75 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
551 | - </tr> | ||
552 | - <tr class="ddrTR"> | ||
553 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1226.05 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
554 | - </tr> | ||
555 | - <tr class="ddrTR"> | ||
556 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">535.38 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
557 | - </tr> | ||
558 | - <tr class="ddrTR"> | ||
559 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">868.84 kg</td><td class="ddrTD">643 m3</td><td class="ddrTD">771.19 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
560 | - </tr> | ||
561 | - <tr class="ddrTR"> | ||
562 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">514.67 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
563 | - </tr> | ||
564 | - <tr class="ddrTR"> | ||
565 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">34.7 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
566 | - </tr> | ||
567 | - <tr class="ddrTR"> | ||
568 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1046.39 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
569 | - </tr> | ||
570 | - <tr class="ddrTR"> | ||
571 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">713.23 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
572 | - </tr> | ||
573 | - <tr class="ddrTR"> | ||
574 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1652 m3</td><td class="ddrTD"></td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
575 | - </tr> | ||
576 | - <tr class="ddrTR"> | ||
577 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">989 m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
578 | - </tr> | ||
579 | - <tr class="ddrTR"> | ||
580 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1010 m3</td><td class="ddrTD"></td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
581 | - </tr> | ||
582 | - <tr class="ddrTR"> | ||
583 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1289.02 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
584 | - </tr> | ||
585 | - <tr class="ddrTR"> | ||
586 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1196.76 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
587 | - </tr> | ||
588 | - <tr class="ddrTR"> | ||
589 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1840.46 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
590 | - </tr> | ||
591 | - <tr class="ddrTR"> | ||
592 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1439.24 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
593 | - </tr> | ||
594 | - <tr class="ddrTR"> | ||
595 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">45.85 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
596 | - </tr> | ||
597 | - <tr class="ddrTR"> | ||
598 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1603.34 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
599 | - </tr> | ||
600 | - <tr class="ddrTR"> | ||
601 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">565.91 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
602 | - </tr> | ||
603 | - <tr class="ddrTR"> | ||
604 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">568.27 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
605 | - </tr> | ||
606 | - <tr class="ddrTR"> | ||
607 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">902.96 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
608 | - </tr> | ||
609 | - <tr class="ddrTR"> | ||
610 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1336.64 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
611 | - </tr> | ||
612 | - <tr class="ddrTR"> | ||
613 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">231.25 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
614 | - </tr> | ||
615 | - <tr class="ddrTR"> | ||
616 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1447.33 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
617 | - </tr> | ||
618 | - <tr class="ddrTR"> | ||
619 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">74.7 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
620 | - </tr> | ||
621 | - <tr class="ddrTR"> | ||
622 | - <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">643 m3</td><td class="ddrTD"></td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
623 | - </tr> | ||
624 | - </table> | ||
625 | - <br> | ||
626 | - </div> | ||
627 | - <div> | ||
628 | - <hr> | ||
629 | - <h2>Production Inventory</h2> | ||
630 | - <table class="ddrTable"> | ||
631 | - <tr class="ddrTR"> | ||
632 | - <th class="ddrTH" style="text-align: center">Inventory Name</th><th class="ddrTH" style="text-align: center">Inventory Type</th><th class="ddrTH" style="text-align: center">Product</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th> | ||
633 | - </tr> | ||
634 | - <tr class="ddrTR"> | ||
635 | - <td class="ddrTD">Trym allocated inventory volumes allocated inventory</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">970.22 kg</td><td class="ddrTD">1809.57 m3</td><td class="ddrTD">721.29 kg/m3</td> | ||
636 | - </tr> | ||
637 | - <tr class="ddrTR"> | ||
638 | - <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">772.62 kg</td><td class="ddrTD">943.97 m3</td><td class="ddrTD">794.46 kg/m3</td> | ||
639 | - </tr> | ||
640 | - </table> | ||
641 | - <br> | ||
642 | - </div> | ||
643 | - <div> | ||
644 | - <hr> | ||
645 | - <h2>Production Inventory Ownership</h2> | ||
646 | - <table class="ddrTable"> | ||
647 | - <tr class="ddrTR"> | ||
648 | - <th class="ddrTH" style="text-align: center">Inventory Name</th><th class="ddrTH" style="text-align: center">Inventory Type</th><th class="ddrTH" style="text-align: center">Product</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Owner</th> | ||
649 | - </tr> | ||
650 | - <tr class="ddrTR"> | ||
651 | - <td class="ddrTD">Trym allocated inventory volumes allocated inventory</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">1441.5 m3</td><td class="ddrTD">DONG E&P Norge AS</td> | ||
652 | - </tr> | ||
653 | - <tr class="ddrTR"> | ||
654 | - <td class="ddrTD">Trym allocated inventory volumes allocated inventory</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">368.07 m3</td><td class="ddrTD">Bayerngas Norge AS</td> | ||
655 | - </tr> | ||
656 | - <tr class="ddrTR"> | ||
657 | - <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">52.3 m3</td><td class="ddrTD">Bayerngas Norge AS</td> | ||
658 | - </tr> | ||
659 | - <tr class="ddrTR"> | ||
660 | - <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">891.67 m3</td><td class="ddrTD">DONG E&P Norge AS</td> | ||
661 | - </tr> | ||
662 | - </table> | ||
663 | - <br> | ||
664 | - </div> | ||
665 | - <div> | ||
666 | - <hr> | ||
667 | - <h2>Fluid Sample Report</h2> | ||
668 | - <table class="ddrTable"> | ||
669 | - <tr class="ddrTR"> | ||
670 | - <th class="ddrTH" style="text-align: center">Sample Type</th><th class="ddrTH" style="text-align: center">Aquisition Date</th><th class="ddrTH" style="text-align: center">Sampling Facility</th><th class="ddrTH" style="text-align: center">Fluid Sample Name</th> | ||
671 | - </tr> | ||
672 | - <tr class="ddrTR"> | ||
673 | - <td class="ddrTD">fluid sampling - separator gas</td><td class="ddrTD">2012-02-15</td><td class="ddrTD">TRYM</td><td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td> | ||
674 | - </tr> | ||
675 | - <tr class="ddrTR"> | ||
676 | - <td class="ddrTD">fluid sampling - separator oil</td><td class="ddrTD">2012-02-13</td><td class="ddrTD">TRYM</td><td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td> | ||
677 | - </tr> | ||
678 | - </table> | ||
679 | - <br> | ||
680 | - </div> | ||
681 | - <div> | ||
682 | - <hr> | ||
683 | - <h2>Fluid Sample Analysis Results</h2> | ||
684 | - <table class="ddrTable"> | ||
685 | - <tr class="ddrTR"> | ||
686 | - <th class="ddrTH" style="text-align: center">Fluid Sample Name</th><th class="ddrTH" style="text-align: center">Component</th><th class="ddrTH" style="text-align: center">Mole Ratio</th><th class="ddrTH" style="text-align: center">Mass Ratio</th><th class="ddrTH" style="text-align: center">Is Primary</th> | ||
687 | - </tr> | ||
688 | - <tr class="ddrTR"> | ||
689 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">normal pentane</td><td class="ddrTD">82 %</td><td class="ddrTD">82 %</td><td class="ddrTD"></td> | ||
690 | - </tr> | ||
691 | - <tr class="ddrTR"> | ||
692 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">ethane</td><td class="ddrTD">0.4 %</td><td class="ddrTD">0.4 %</td><td class="ddrTD"></td> | ||
693 | - </tr> | ||
694 | - <tr class="ddrTR"> | ||
695 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">normal butane</td><td class="ddrTD">4 %</td><td class="ddrTD">4 %</td><td class="ddrTD"></td> | ||
696 | - </tr> | ||
697 | - <tr class="ddrTR"> | ||
698 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">C6+</td><td class="ddrTD">2.5 %</td><td class="ddrTD">2.5 %</td><td class="ddrTD"></td> | ||
699 | - </tr> | ||
700 | - <tr class="ddrTR"> | ||
701 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">propane</td><td class="ddrTD">0.64 %</td><td class="ddrTD">0.64 %</td><td class="ddrTD"></td> | ||
702 | - </tr> | ||
703 | - <tr class="ddrTR"> | ||
704 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">CO2</td><td class="ddrTD">1 %</td><td class="ddrTD">1 %</td><td class="ddrTD"></td> | ||
705 | - </tr> | ||
706 | - <tr class="ddrTR"> | ||
707 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">isobutane</td><td class="ddrTD">1.46 %</td><td class="ddrTD">1.46 %</td><td class="ddrTD"></td> | ||
708 | - </tr> | ||
709 | - <tr class="ddrTR"> | ||
710 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">N2</td><td class="ddrTD">1.9 %</td><td class="ddrTD">1.9 %</td><td class="ddrTD"></td> | ||
711 | - </tr> | ||
712 | - <tr class="ddrTR"> | ||
713 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">C1</td><td class="ddrTD">0.1 %</td><td class="ddrTD">0.1 %</td><td class="ddrTD"></td> | ||
714 | - </tr> | ||
715 | - <tr class="ddrTR"> | ||
716 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">isopentane</td><td class="ddrTD">6 %</td><td class="ddrTD">6 %</td><td class="ddrTD"></td> | ||
717 | - </tr> | ||
718 | - <tr class="ddrTR"> | ||
719 | - <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">True</td> | ||
720 | - </tr> | ||
721 | - <tr class="ddrTR"> | ||
722 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">N2</td><td class="ddrTD">1.9 %</td><td class="ddrTD">1.9 %</td><td class="ddrTD"></td> | ||
723 | - </tr> | ||
724 | - <tr class="ddrTR"> | ||
725 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">CO2</td><td class="ddrTD">1 %</td><td class="ddrTD">1 %</td><td class="ddrTD"></td> | ||
726 | - </tr> | ||
727 | - <tr class="ddrTR"> | ||
728 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">normal butane</td><td class="ddrTD">4 %</td><td class="ddrTD">4 %</td><td class="ddrTD"></td> | ||
729 | - </tr> | ||
730 | - <tr class="ddrTR"> | ||
731 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">isobutane</td><td class="ddrTD">1.46 %</td><td class="ddrTD">1.46 %</td><td class="ddrTD"></td> | ||
732 | - </tr> | ||
733 | - <tr class="ddrTR"> | ||
734 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">normal pentane</td><td class="ddrTD">82 %</td><td class="ddrTD">82 %</td><td class="ddrTD"></td> | ||
735 | - </tr> | ||
736 | - <tr class="ddrTR"> | ||
737 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">propane</td><td class="ddrTD">0.64 %</td><td class="ddrTD">0.64 %</td><td class="ddrTD"></td> | ||
738 | - </tr> | ||
739 | - <tr class="ddrTR"> | ||
740 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">isopentane</td><td class="ddrTD">6 %</td><td class="ddrTD">6 %</td><td class="ddrTD"></td> | ||
741 | - </tr> | ||
742 | - <tr class="ddrTR"> | ||
743 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">C1</td><td class="ddrTD">0.1 %</td><td class="ddrTD">0.1 %</td><td class="ddrTD"></td> | ||
744 | - </tr> | ||
745 | - <tr class="ddrTR"> | ||
746 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">C6+</td><td class="ddrTD">2.5 %</td><td class="ddrTD">2.5 %</td><td class="ddrTD"></td> | ||
747 | - </tr> | ||
748 | - <tr class="ddrTR"> | ||
749 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">ethane</td><td class="ddrTD">0.4 %</td><td class="ddrTD">0.4 %</td><td class="ddrTD"></td> | ||
750 | - </tr> | ||
751 | - <tr class="ddrTR"> | ||
752 | - <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">C7+</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">True</td> | ||
753 | - </tr> | ||
754 | - </table> | ||
755 | - <br> | ||
756 | - </div> | ||
757 | - <div> | ||
758 | - <hr> | ||
759 | - <h2>Well Test Report Summary</h2> | ||
760 | - <table class="ddrTable"> | ||
761 | - <tr class="ddrTR"> | ||
762 | - <th class="ddrTH" style="text-align: center">Wellbore</th><th class="ddrTH" style="text-align: center">Test Type</th><th class="ddrTH" style="text-align: center">Activity</th><th class="ddrTH" style="text-align: center">Reason</th><th class="ddrTH" style="text-align: center">Started or Nominally At</th><th class="ddrTH" style="text-align: center">Duration</th><th class="ddrTH" style="text-align: center">Description </th><th class="ddrTH" style="text-align: center">Predecessor At</th><th class="ddrTH" style="text-align: center">Last Valid At</th> | ||
763 | - </tr> | ||
764 | - <tr class="ddrTR"> | ||
765 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">maximum sand-free rate test</td><td class="ddrTD"></td><td class="ddrTD">other reason well text</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD"></td><td class="ddrTD">Injection well test for well 3/7-A-1 AH</td><td class="ddrTD">2012-02-15T00:00:00.0Z</td><td class="ddrTD">2012-02-26T00:00:00.0Z</td> | ||
766 | - </tr> | ||
767 | - <tr class="ddrTR"> | ||
768 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">pressure build-up test</td><td class="ddrTD"></td><td class="ddrTD">periodic well test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">3 h</td><td class="ddrTD">Injection well test for well 3/7-A-1 AH</td><td class="ddrTD">2012-02-11T00:00:00.0Z</td><td class="ddrTD">2012-02-23T00:00:00.0Z</td> | ||
769 | - </tr> | ||
770 | - <tr class="ddrTR"> | ||
771 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">multi-layer transient test</td><td class="ddrTD">production well test</td><td class="ddrTD">other reason well text</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">8 h</td><td class="ddrTD">Production well test for well 3/7-A-1 AH</td><td class="ddrTD">2012-02-14T00:00:00.0Z</td><td class="ddrTD">2012-02-22T00:00:00.0Z</td> | ||
772 | - </tr> | ||
773 | - <tr class="ddrTR"> | ||
774 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">gas - flow after flow test</td><td class="ddrTD">production well test</td><td class="ddrTD">initial well test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">5 h</td><td class="ddrTD">Production well test for well 3/7-A-2 H</td><td class="ddrTD">2012-02-19T00:00:00.0Z</td><td class="ddrTD">2012-02-25T00:00:00.0Z</td> | ||
775 | - </tr> | ||
776 | - <tr class="ddrTR"> | ||
777 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">injection test - fall-off</td><td class="ddrTD"></td><td class="ddrTD">initial well test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD"></td><td class="ddrTD">Injection well test for well 3/7-A-2 H</td><td class="ddrTD">2012-02-19T00:00:00.0Z</td><td class="ddrTD">2012-02-28T00:00:00.0Z</td> | ||
778 | - </tr> | ||
779 | - <tr class="ddrTR"> | ||
780 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">maximum sand-free rate test</td><td class="ddrTD"></td><td class="ddrTD">periodic well test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">6 h</td><td class="ddrTD">Injection well test for well 3/7-A-2 H</td><td class="ddrTD">2012-02-11T00:00:00.0Z</td><td class="ddrTD">2012-02-29T00:00:00.0Z</td> | ||
781 | - </tr> | ||
782 | - </table> | ||
783 | - <br> | ||
784 | - </div> | ||
785 | - <div> | ||
786 | - <hr> | ||
787 | - <h2>Well Injection Tests</h2> | ||
788 | - <table class="ddrTable"> | ||
789 | - <tr class="ddrTR"> | ||
790 | - <th class="ddrTH" style="text-align: center">Wellbore</th><th class="ddrTH" style="text-align: center">Test Type</th><th class="ddrTH" style="text-align: center">Nominally At</th><th class="ddrTH" style="text-align: center">Duration</th><th class="ddrTH" style="text-align: center">Injected<br>Fluid</th><th class="ddrTH" style="text-align: center">Reason</th><th class="ddrTH" style="text-align: center">Min <br>Annular <br>Pressure</th><th class="ddrTH" style="text-align: center">Max <br>Annular <br>Pressure</th><th class="ddrTH" style="text-align: center">Wellhead <br>Flowing <br>Pressure</th><th class="ddrTH" style="text-align: center">Wellhead <br>Max <br>Pressure</th><th class="ddrTH" style="text-align: center">Choke</th> | ||
791 | - </tr> | ||
792 | - <tr class="ddrTR"> | ||
793 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">pressure build-up test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">3 h</td><td class="ddrTD">gas</td><td class="ddrTD">periodic well test</td><td class="ddrTD">187.36 bar</td><td class="ddrTD">229.13 bar</td><td class="ddrTD">86.41 bar</td><td class="ddrTD">106.55 bar</td><td class="ddrTD">92.63 in/64</td> | ||
794 | - </tr> | ||
795 | - <tr class="ddrTR"> | ||
796 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">maximum sand-free rate test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">6 h</td><td class="ddrTD"></td><td class="ddrTD">periodic well test</td><td class="ddrTD">176.82 bar</td><td class="ddrTD">225.91 bar</td><td class="ddrTD">86.15 bar</td><td class="ddrTD">100.16 bar</td><td class="ddrTD">84.8 in/64</td> | ||
797 | - </tr> | ||
798 | - </table> | ||
799 | - <br> | ||
800 | - </div> | ||
801 | - <div> | ||
802 | - <hr> | ||
803 | - <h2>Well Injection Test Results</h2> | ||
804 | - <table class="ddrTable"> | ||
805 | - <tr class="ddrTR"> | ||
806 | - <th class="ddrTH" style="text-align: center">Wellbore</th><th class="ddrTH" style="text-align: center">Test Type</th><th class="ddrTH" style="text-align: center">Nominally At</th><th class="ddrTH" style="text-align: center">Oil Rate</th><th class="ddrTH" style="text-align: center">Oil Volume</th><th class="ddrTH" style="text-align: center">Oil Density</th><th class="ddrTH" style="text-align: center">Gas Rate</th><th class="ddrTH" style="text-align: center">Gas Volume</th><th class="ddrTH" style="text-align: center">Gas Density</th><th class="ddrTH" style="text-align: center">Water Rate</th><th class="ddrTH" style="text-align: center">Water Volume</th> | ||
807 | - </tr> | ||
808 | - <tr class="ddrTR"> | ||
809 | - <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">pressure build-up test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">637.86 m3/h</td><td class="ddrTD">3518.44 m3</td><td class="ddrTD">770.79 kg/m3</td><td class="ddrTD">3763.86 m3/h</td><td class="ddrTD">5511.75 m3</td><td class="ddrTD">1.65 kg/m3</td><td class="ddrTD">113.18 m3/h</td><td class="ddrTD">112.59 m3</td> | ||
810 | - </tr> | ||
811 | - <tr class="ddrTR"> | ||
812 | - <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">maximum sand-free rate test</td><td class="ddrTD">2012-03-01T00:00:00.0Z</td><td class="ddrTD">776.11 m3/h</td><td class="ddrTD">3616.33 m3</td><td class="ddrTD">740.88 kg/m3</td><td class="ddrTD">3648.39 m3/h</td><td class="ddrTD">6500.64 m3</td><td class="ddrTD">1.58 kg/m3</td><td class="ddrTD">132.79 m3/h</td><td class="ddrTD">160.23 m3</td> | ||
813 | - </tr> | ||
814 | - </table> | ||
815 | - <br> | ||
816 | - </div> | ||
817 | - </body> | ||
818 | -</html> |
1 | +<!DOCTYPE html> | ||
2 | +<html> | ||
3 | + <head> | ||
4 | + <META http-equiv="Content-Type" content="text/html; charset=utf-8"> | ||
5 | + <link href="http://spinrdf.org/rhlib/ddr.css" rel="stylesheet" type="text/css"> | ||
6 | + <title>Monthly Production Report (Partner)</title> | ||
7 | + </head> | ||
8 | + <body> | ||
9 | + <h1>Monthly Partner Report : TRYM Field, Month Ending 2012-03-31</h1> | ||
10 | + <h2>Report title : TRYM all</h2> | ||
11 | + <h2>Report Status : final version of a report</h2> | ||
12 | + <h2>Submitted by : TRYM</h2> | ||
13 | + <div> | ||
14 | + <hr> | ||
15 | + <h2>Gas Sales</h2> | ||
16 | + <table class="ddrTable"> | ||
17 | + <tr class="ddrTR"> | ||
18 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Seller</th><th class="ddrTH" style="text-align: center">Seller Volume</th><th class="ddrTH" style="text-align: center">Seller Work</th><th class="ddrTH" style="text-align: center">Buyer</th><th class="ddrTH" style="text-align: center">Buyer Volume</th><th class="ddrTH" style="text-align: center">Buyer Work</th> | ||
19 | + </tr> | ||
20 | + <tr class="ddrTR"> | ||
21 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">7633.81 m3</td><td class="ddrTD">21807.81 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">7633.81 m3</td><td class="ddrTD">28016.28 MJ</td> | ||
22 | + </tr> | ||
23 | + <tr class="ddrTR"> | ||
24 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1052.42 m3</td><td class="ddrTD">31669.11 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">1052.42 m3</td><td class="ddrTD">29208.32 MJ</td> | ||
25 | + </tr> | ||
26 | + <tr class="ddrTR"> | ||
27 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas - dry</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">1572.85 m3</td><td class="ddrTD">42489.02 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">1572.85 m3</td><td class="ddrTD">11035.79 MJ</td> | ||
28 | + </tr> | ||
29 | + <tr class="ddrTR"> | ||
30 | + <td class="ddrTD">TRYM</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">14003.79 m3</td><td class="ddrTD">28868.02 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">14003.79 m3</td><td class="ddrTD">57642.8 MJ</td> | ||
31 | + </tr> | ||
32 | + <tr class="ddrTR"> | ||
33 | + <td class="ddrTD">TRYM</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">14543.62 m3</td><td class="ddrTD">72341.85 MJ</td><td class="ddrTD">NATURGASS FYN</td><td class="ddrTD">14543.62 m3</td><td class="ddrTD">44305.85 MJ</td> | ||
34 | + </tr> | ||
35 | + <tr class="ddrTR"> | ||
36 | + <td class="ddrTD">TRYM</td><td class="ddrTD">flow to sale</td><td class="ddrTD">gas</td><td class="ddrTD">allocated flow</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">14818.92 m3</td><td class="ddrTD">20284.2 MJ</td><td class="ddrTD">NATURGAS VEST</td><td class="ddrTD">14818.92 m3</td><td class="ddrTD">22557.98 MJ</td> | ||
37 | + </tr> | ||
38 | + </table> | ||
39 | + <br> | ||
40 | + </div> | ||
41 | + <div> | ||
42 | + <hr> | ||
43 | + <h2>Well Production</h2> | ||
44 | + <table class="ddrTable"> | ||
45 | + <tr class="ddrTR"> | ||
46 | + <th class="ddrTH" style="text-align: center">Wellbore</th><th class="ddrTH" style="text-align: center">Status</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Day</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
47 | + </tr> | ||
48 | + <tr class="ddrTR"> | ||
49 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1408 m3</td><td class="ddrTD">21</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
50 | + </tr> | ||
51 | + <tr class="ddrTR"> | ||
52 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1164.82 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
53 | + </tr> | ||
54 | + <tr class="ddrTR"> | ||
55 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1159.02 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
56 | + </tr> | ||
57 | + <tr class="ddrTR"> | ||
58 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1870.37 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
59 | + </tr> | ||
60 | + <tr class="ddrTR"> | ||
61 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1771.66 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
62 | + </tr> | ||
63 | + <tr class="ddrTR"> | ||
64 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1408 m3</td><td class="ddrTD">21</td><td class="ddrTD">allocated flow</td><td class="ddrTD">net product flow</td> | ||
65 | + </tr> | ||
66 | + <tr class="ddrTR"> | ||
67 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">158.72 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
68 | + </tr> | ||
69 | + <tr class="ddrTR"> | ||
70 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">117.18 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
71 | + </tr> | ||
72 | + <tr class="ddrTR"> | ||
73 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1487.81 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
74 | + </tr> | ||
75 | + <tr class="ddrTR"> | ||
76 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1868.88 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
77 | + </tr> | ||
78 | + <tr class="ddrTR"> | ||
79 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1408 m3</td><td class="ddrTD">21</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
80 | + </tr> | ||
81 | + <tr class="ddrTR"> | ||
82 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1458.15 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
83 | + </tr> | ||
84 | + <tr class="ddrTR"> | ||
85 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">652.18 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
86 | + </tr> | ||
87 | + <tr class="ddrTR"> | ||
88 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">779.47 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
89 | + </tr> | ||
90 | + <tr class="ddrTR"> | ||
91 | + <td class="ddrTD">3/7-A-1 AH</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">910.93 m3</td><td class="ddrTD">21</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
92 | + </tr> | ||
93 | + <tr class="ddrTR"> | ||
94 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1775.09 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
95 | + </tr> | ||
96 | + <tr class="ddrTR"> | ||
97 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1945.29 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
98 | + </tr> | ||
99 | + <tr class="ddrTR"> | ||
100 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">1531.67 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
101 | + </tr> | ||
102 | + <tr class="ddrTR"> | ||
103 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">26.88 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
104 | + </tr> | ||
105 | + <tr class="ddrTR"> | ||
106 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">585 m3</td><td class="ddrTD">5</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
107 | + </tr> | ||
108 | + <tr class="ddrTR"> | ||
109 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1070.53 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
110 | + </tr> | ||
111 | + <tr class="ddrTR"> | ||
112 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1139.56 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
113 | + </tr> | ||
114 | + <tr class="ddrTR"> | ||
115 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">412.71 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
116 | + </tr> | ||
117 | + <tr class="ddrTR"> | ||
118 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">1208.85 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD">net product flow</td> | ||
119 | + </tr> | ||
120 | + <tr class="ddrTR"> | ||
121 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">585 m3</td><td class="ddrTD">5</td><td class="ddrTD">allocated flow</td><td class="ddrTD">net product flow</td> | ||
122 | + </tr> | ||
123 | + <tr class="ddrTR"> | ||
124 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">202.05 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
125 | + </tr> | ||
126 | + <tr class="ddrTR"> | ||
127 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">1903.46 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
128 | + </tr> | ||
129 | + <tr class="ddrTR"> | ||
130 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">9.68 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
131 | + </tr> | ||
132 | + <tr class="ddrTR"> | ||
133 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">492.44 m3</td><td class="ddrTD">5</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td> | ||
134 | + </tr> | ||
135 | + <tr class="ddrTR"> | ||
136 | + <td class="ddrTD">3/7-A-2 H</td><td class="ddrTD">producing well</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD">585 m3</td><td class="ddrTD">5</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td> | ||
137 | + </tr> | ||
138 | + </table> | ||
139 | + <br> | ||
140 | + </div> | ||
141 | + <div> | ||
142 | + <hr> | ||
143 | + <h2>Cargo Information</h2> | ||
144 | + <table class="ddrTable"> | ||
145 | + <tr class="ddrTR"> | ||
146 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Cargo Number</th><th class="ddrTH" style="text-align: center">Cargo Batch</th><th class="ddrTH" style="text-align: center">Bill of Lading</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Shipper</th><th class="ddrTH" style="text-align: center">Destination</th><th class="ddrTH" style="text-align: center">Country</th><th class="ddrTH" style="text-align: center">Owner</th><th class="ddrTH" style="text-align: center">Share</th> | ||
147 | + </tr> | ||
148 | + <tr class="ddrTR"> | ||
149 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">340/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">674.69 m3</td><td class="ddrTD">452.42 kg</td><td class="ddrTD">710.52 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
150 | + </tr> | ||
151 | + <tr class="ddrTR"> | ||
152 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">340/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">674.69 m3</td><td class="ddrTD">452.42 kg</td><td class="ddrTD">710.52 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
153 | + </tr> | ||
154 | + <tr class="ddrTR"> | ||
155 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">341/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">299.56 m3</td><td class="ddrTD">238.93 kg</td><td class="ddrTD">718.55 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
156 | + </tr> | ||
157 | + <tr class="ddrTR"> | ||
158 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">341/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">299.56 m3</td><td class="ddrTD">238.93 kg</td><td class="ddrTD">718.55 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
159 | + </tr> | ||
160 | + <tr class="ddrTR"> | ||
161 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">342/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">531.2 m3</td><td class="ddrTD">412.64 kg</td><td class="ddrTD">776.18 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
162 | + </tr> | ||
163 | + <tr class="ddrTR"> | ||
164 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">342/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">531.2 m3</td><td class="ddrTD">412.64 kg</td><td class="ddrTD">776.18 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
165 | + </tr> | ||
166 | + <tr class="ddrTR"> | ||
167 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">352/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-04</td><td class="ddrTD">1963.57 m3</td><td class="ddrTD">814.19 kg</td><td class="ddrTD">783.65 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
168 | + </tr> | ||
169 | + <tr class="ddrTR"> | ||
170 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">352/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-04</td><td class="ddrTD">1963.57 m3</td><td class="ddrTD">814.19 kg</td><td class="ddrTD">783.65 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
171 | + </tr> | ||
172 | + <tr class="ddrTR"> | ||
173 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">353/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">69.98 m3</td><td class="ddrTD">749.99 kg</td><td class="ddrTD">701.76 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
174 | + </tr> | ||
175 | + <tr class="ddrTR"> | ||
176 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">353/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">69.98 m3</td><td class="ddrTD">749.99 kg</td><td class="ddrTD">701.76 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
177 | + </tr> | ||
178 | + <tr class="ddrTR"> | ||
179 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">354/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1866.73 m3</td><td class="ddrTD">645.09 kg</td><td class="ddrTD">777.51 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
180 | + </tr> | ||
181 | + <tr class="ddrTR"> | ||
182 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">354/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1866.73 m3</td><td class="ddrTD">645.09 kg</td><td class="ddrTD">777.51 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
183 | + </tr> | ||
184 | + <tr class="ddrTR"> | ||
185 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">355/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-15</td><td class="ddrTD">453.45 m3</td><td class="ddrTD">259.21 kg</td><td class="ddrTD">723.31 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
186 | + </tr> | ||
187 | + <tr class="ddrTR"> | ||
188 | + <td class="ddrTD">FREDERICIA</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">355/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-15</td><td class="ddrTD">453.45 m3</td><td class="ddrTD">259.21 kg</td><td class="ddrTD">723.31 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
189 | + </tr> | ||
190 | + <tr class="ddrTR"> | ||
191 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">340/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">674.69 m3</td><td class="ddrTD">452.42 kg</td><td class="ddrTD">710.52 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
192 | + </tr> | ||
193 | + <tr class="ddrTR"> | ||
194 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">341/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">299.56 m3</td><td class="ddrTD">238.93 kg</td><td class="ddrTD">718.55 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
195 | + </tr> | ||
196 | + <tr class="ddrTR"> | ||
197 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">342/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">531.2 m3</td><td class="ddrTD">412.64 kg</td><td class="ddrTD">776.18 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
198 | + </tr> | ||
199 | + <tr class="ddrTR"> | ||
200 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">352/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-04</td><td class="ddrTD">1963.57 m3</td><td class="ddrTD">814.19 kg</td><td class="ddrTD">783.65 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
201 | + </tr> | ||
202 | + <tr class="ddrTR"> | ||
203 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">353/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">69.98 m3</td><td class="ddrTD">749.99 kg</td><td class="ddrTD">701.76 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
204 | + </tr> | ||
205 | + <tr class="ddrTR"> | ||
206 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">354/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1866.73 m3</td><td class="ddrTD">645.09 kg</td><td class="ddrTD">777.51 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
207 | + </tr> | ||
208 | + <tr class="ddrTR"> | ||
209 | + <td class="ddrTD">NYBRO</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">355/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-15</td><td class="ddrTD">453.45 m3</td><td class="ddrTD">259.21 kg</td><td class="ddrTD">723.31 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
210 | + </tr> | ||
211 | + <tr class="ddrTR"> | ||
212 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">340/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">674.69 m3</td><td class="ddrTD">452.42 kg</td><td class="ddrTD">710.52 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
213 | + </tr> | ||
214 | + <tr class="ddrTR"> | ||
215 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">340/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-06</td><td class="ddrTD">674.69 m3</td><td class="ddrTD">452.42 kg</td><td class="ddrTD">710.52 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
216 | + </tr> | ||
217 | + <tr class="ddrTR"> | ||
218 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">341/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">299.56 m3</td><td class="ddrTD">238.93 kg</td><td class="ddrTD">718.55 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
219 | + </tr> | ||
220 | + <tr class="ddrTR"> | ||
221 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">341/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-11</td><td class="ddrTD">299.56 m3</td><td class="ddrTD">238.93 kg</td><td class="ddrTD">718.55 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
222 | + </tr> | ||
223 | + <tr class="ddrTR"> | ||
224 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">342/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">531.2 m3</td><td class="ddrTD">412.64 kg</td><td class="ddrTD">776.18 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
225 | + </tr> | ||
226 | + <tr class="ddrTR"> | ||
227 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">342/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-16</td><td class="ddrTD">531.2 m3</td><td class="ddrTD">412.64 kg</td><td class="ddrTD">776.18 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">100 %</td> | ||
228 | + </tr> | ||
229 | + <tr class="ddrTR"> | ||
230 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">352/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-04</td><td class="ddrTD">1963.57 m3</td><td class="ddrTD">814.19 kg</td><td class="ddrTD">783.65 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
231 | + </tr> | ||
232 | + <tr class="ddrTR"> | ||
233 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">352/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-04</td><td class="ddrTD">1963.57 m3</td><td class="ddrTD">814.19 kg</td><td class="ddrTD">783.65 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Rotterdam</td><td class="ddrTD">NETHERLANDS</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
234 | + </tr> | ||
235 | + <tr class="ddrTR"> | ||
236 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">353/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">69.98 m3</td><td class="ddrTD">749.99 kg</td><td class="ddrTD">701.76 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
237 | + </tr> | ||
238 | + <tr class="ddrTR"> | ||
239 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">353/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-09</td><td class="ddrTD">69.98 m3</td><td class="ddrTD">749.99 kg</td><td class="ddrTD">701.76 kg/m3</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">MONGSTAD</td><td class="ddrTD">NORWAY</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
240 | + </tr> | ||
241 | + <tr class="ddrTR"> | ||
242 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">354/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1866.73 m3</td><td class="ddrTD">645.09 kg</td><td class="ddrTD">777.51 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
243 | + </tr> | ||
244 | + <tr class="ddrTR"> | ||
245 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">354/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-12</td><td class="ddrTD">1866.73 m3</td><td class="ddrTD">645.09 kg</td><td class="ddrTD">777.51 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
246 | + </tr> | ||
247 | + <tr class="ddrTR"> | ||
248 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">355/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-15</td><td class="ddrTD">453.45 m3</td><td class="ddrTD">259.21 kg</td><td class="ddrTD">723.31 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
249 | + </tr> | ||
250 | + <tr class="ddrTR"> | ||
251 | + <td class="ddrTD">TRYM</td><td class="ddrTD">oil net</td><td class="ddrTD">allocated flow</td><td class="ddrTD">355/1</td><td class="ddrTD">1</td><td class="ddrTD">2012-01-15</td><td class="ddrTD">453.45 m3</td><td class="ddrTD">259.21 kg</td><td class="ddrTD">723.31 kg/m3</td><td class="ddrTD">Bayerngas Norge AS</td><td class="ddrTD">Fawley</td><td class="ddrTD">UNITED KINGDOM</td><td class="ddrTD">DONG E&P Norge AS</td><td class="ddrTD">100 %</td> | ||
252 | + </tr> | ||
253 | + </table> | ||
254 | + <br> | ||
255 | + </div> | ||
256 | + <div> | ||
257 | + <hr> | ||
258 | + <h2>Production Saleable</h2> | ||
259 | + <table class="ddrTable"> | ||
260 | + <tr class="ddrTR"> | ||
261 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
262 | + </tr> | ||
263 | + <tr class="ddrTR"> | ||
264 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">716.74 kg</td><td class="ddrTD">235.44 m3</td><td class="ddrTD">723.41 kg/m3</td><td class="ddrTD">saleable flow</td><td class="ddrTD">net product flow</td> | ||
265 | + </tr> | ||
266 | + </table> | ||
267 | + <br> | ||
268 | + </div> | ||
269 | + <div> | ||
270 | + <hr> | ||
271 | + <h2>Production</h2> | ||
272 | + <table class="ddrTable"> | ||
273 | + <tr class="ddrTR"> | ||
274 | + <th class="ddrTH" style="text-align: center">Facility</th><th class="ddrTH" style="text-align: center">Purpose</th><th class="ddrTH" style="text-align: center">Material</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th><th class="ddrTH" style="text-align: center">Flow type</th><th class="ddrTH" style="text-align: center">Flow subtype</th><th class="ddrTH" style="text-align: center">Gross/Net</th> | ||
275 | + </tr> | ||
276 | + <tr class="ddrTR"> | ||
277 | + <td class="ddrTD">TRYM</td><td class="ddrTD">consumption flow - flare</td><td class="ddrTD">gas</td><td class="ddrTD">39276532.29 kg</td><td class="ddrTD">415745.31 m3</td><td class="ddrTD">0.79 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
278 | + </tr> | ||
279 | + <tr class="ddrTR"> | ||
280 | + <td class="ddrTD">TRYM</td><td class="ddrTD">consumption flow - fuel</td><td class="ddrTD">diesel</td><td class="ddrTD"></td><td class="ddrTD">242.83 litre</td><td class="ddrTD"></td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
281 | + </tr> | ||
282 | + <tr class="ddrTR"> | ||
283 | + <td class="ddrTD">TRYM</td><td class="ddrTD">consumption flow - fuel</td><td class="ddrTD">gas</td><td class="ddrTD">35300156.7 kg</td><td class="ddrTD">300831.6 m3</td><td class="ddrTD">0.98 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
284 | + </tr> | ||
285 | + <tr class="ddrTR"> | ||
286 | + <td class="ddrTD">TRYM</td><td class="ddrTD">export</td><td class="ddrTD">oil gross</td><td class="ddrTD">73372567.44 kg</td><td class="ddrTD">139441 m3</td><td class="ddrTD">772.72 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD">gross product flow</td> | ||
287 | + </tr> | ||
288 | + <tr class="ddrTR"> | ||
289 | + <td class="ddrTD">TRYM</td><td class="ddrTD">injection flow</td><td class="ddrTD">gas</td><td class="ddrTD">36306949.89 kg</td><td class="ddrTD">387294 m3</td><td class="ddrTD">0.97 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
290 | + </tr> | ||
291 | + <tr class="ddrTR"> | ||
292 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD"></td><td class="ddrTD">78594123.55 kg</td><td class="ddrTD">110206 m3</td><td class="ddrTD">785.34 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
293 | + </tr> | ||
294 | + <tr class="ddrTR"> | ||
295 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD"></td><td class="ddrTD">71725170.31 kg</td><td class="ddrTD">110206 m3</td><td class="ddrTD">790.81 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
296 | + </tr> | ||
297 | + <tr class="ddrTR"> | ||
298 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">996.47 kg</td><td class="ddrTD">1371.6 m3</td><td class="ddrTD">793.5 kg/m3</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
299 | + </tr> | ||
300 | + <tr class="ddrTR"> | ||
301 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">228.14 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
302 | + </tr> | ||
303 | + <tr class="ddrTR"> | ||
304 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1411.48 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
305 | + </tr> | ||
306 | + <tr class="ddrTR"> | ||
307 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1025.28 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
308 | + </tr> | ||
309 | + <tr class="ddrTR"> | ||
310 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">20.44 kg</td><td class="ddrTD">1606 m3</td><td class="ddrTD">757.94 kg/m3</td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
311 | + </tr> | ||
312 | + <tr class="ddrTR"> | ||
313 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">705.73 kg</td><td class="ddrTD">702 m3</td><td class="ddrTD">784.14 kg/m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
314 | + </tr> | ||
315 | + <tr class="ddrTR"> | ||
316 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">465.33 kg</td><td class="ddrTD">1898 m3</td><td class="ddrTD">794.95 kg/m3</td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
317 | + </tr> | ||
318 | + <tr class="ddrTR"> | ||
319 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">487.14 kg</td><td class="ddrTD">1608.89 m3</td><td class="ddrTD">757.95 kg/m3</td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
320 | + </tr> | ||
321 | + <tr class="ddrTR"> | ||
322 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1967.01 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
323 | + </tr> | ||
324 | + <tr class="ddrTR"> | ||
325 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1449.68 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
326 | + </tr> | ||
327 | + <tr class="ddrTR"> | ||
328 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">746.04 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
329 | + </tr> | ||
330 | + <tr class="ddrTR"> | ||
331 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">899.22 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
332 | + </tr> | ||
333 | + <tr class="ddrTR"> | ||
334 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1545.79 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
335 | + </tr> | ||
336 | + <tr class="ddrTR"> | ||
337 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">998.9 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
338 | + </tr> | ||
339 | + <tr class="ddrTR"> | ||
340 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1063.01 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
341 | + </tr> | ||
342 | + <tr class="ddrTR"> | ||
343 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1529.89 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
344 | + </tr> | ||
345 | + <tr class="ddrTR"> | ||
346 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">1218.32 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
347 | + </tr> | ||
348 | + <tr class="ddrTR"> | ||
349 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">283.8 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
350 | + </tr> | ||
351 | + <tr class="ddrTR"> | ||
352 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">389.55 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
353 | + </tr> | ||
354 | + <tr class="ddrTR"> | ||
355 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD"></td><td class="ddrTD">498.56 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
356 | + </tr> | ||
357 | + <tr class="ddrTR"> | ||
358 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">condensate net</td><td class="ddrTD">571.65 kg</td><td class="ddrTD">934 m3</td><td class="ddrTD">790.39 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
359 | + </tr> | ||
360 | + <tr class="ddrTR"> | ||
361 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">42.76 kg</td><td class="ddrTD">859.06 m3</td><td class="ddrTD">0.53 kg/m3</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
362 | + </tr> | ||
363 | + <tr class="ddrTR"> | ||
364 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1627.37 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
365 | + </tr> | ||
366 | + <tr class="ddrTR"> | ||
367 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1016.41 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
368 | + </tr> | ||
369 | + <tr class="ddrTR"> | ||
370 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1324.55 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
371 | + </tr> | ||
372 | + <tr class="ddrTR"> | ||
373 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">981.38 kg</td><td class="ddrTD">1606 m3</td><td class="ddrTD">0.69 kg/m3</td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
374 | + </tr> | ||
375 | + <tr class="ddrTR"> | ||
376 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">570.27 kg</td><td class="ddrTD">702 m3</td><td class="ddrTD">0.61 kg/m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
377 | + </tr> | ||
378 | + <tr class="ddrTR"> | ||
379 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">628.6 kg</td><td class="ddrTD">1898 m3</td><td class="ddrTD">0.61 kg/m3</td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
380 | + </tr> | ||
381 | + <tr class="ddrTR"> | ||
382 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1987.18 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
383 | + </tr> | ||
384 | + <tr class="ddrTR"> | ||
385 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">146.32 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
386 | + </tr> | ||
387 | + <tr class="ddrTR"> | ||
388 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">415.46 kg</td><td class="ddrTD">98.46 m3</td><td class="ddrTD">0.53 kg/m3</td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
389 | + </tr> | ||
390 | + <tr class="ddrTR"> | ||
391 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">265.39 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
392 | + </tr> | ||
393 | + <tr class="ddrTR"> | ||
394 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">370.12 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
395 | + </tr> | ||
396 | + <tr class="ddrTR"> | ||
397 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1100.92 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
398 | + </tr> | ||
399 | + <tr class="ddrTR"> | ||
400 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1541.79 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
401 | + </tr> | ||
402 | + <tr class="ddrTR"> | ||
403 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">79.58 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
404 | + </tr> | ||
405 | + <tr class="ddrTR"> | ||
406 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">939.31 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
407 | + </tr> | ||
408 | + <tr class="ddrTR"> | ||
409 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1387.82 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
410 | + </tr> | ||
411 | + <tr class="ddrTR"> | ||
412 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">638.82 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
413 | + </tr> | ||
414 | + <tr class="ddrTR"> | ||
415 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">1285.7 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
416 | + </tr> | ||
417 | + <tr class="ddrTR"> | ||
418 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD">790.29 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
419 | + </tr> | ||
420 | + <tr class="ddrTR"> | ||
421 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">gas</td><td class="ddrTD">266.11 kg</td><td class="ddrTD">934 m3</td><td class="ddrTD">0.55 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
422 | + </tr> | ||
423 | + <tr class="ddrTR"> | ||
424 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">440.62 kg</td><td class="ddrTD">511.11 m3</td><td class="ddrTD">755.8 kg/m3</td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
425 | + </tr> | ||
426 | + <tr class="ddrTR"> | ||
427 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">64.3 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
428 | + </tr> | ||
429 | + <tr class="ddrTR"> | ||
430 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">466.99 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
431 | + </tr> | ||
432 | + <tr class="ddrTR"> | ||
433 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1128.15 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
434 | + </tr> | ||
435 | + <tr class="ddrTR"> | ||
436 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">127.87 kg</td><td class="ddrTD">1606 m3</td><td class="ddrTD">772.43 kg/m3</td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
437 | + </tr> | ||
438 | + <tr class="ddrTR"> | ||
439 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">72027973.16 kg</td><td class="ddrTD">110206 m3</td><td class="ddrTD">767.89 kg/m3</td><td class="ddrTD">metered flow fiscal</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
440 | + </tr> | ||
441 | + <tr class="ddrTR"> | ||
442 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">749.65 kg</td><td class="ddrTD">702 m3</td><td class="ddrTD">795.37 kg/m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
443 | + </tr> | ||
444 | + <tr class="ddrTR"> | ||
445 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">581.2 kg</td><td class="ddrTD">1898 m3</td><td class="ddrTD">799.38 kg/m3</td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
446 | + </tr> | ||
447 | + <tr class="ddrTR"> | ||
448 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1322.68 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
449 | + </tr> | ||
450 | + <tr class="ddrTR"> | ||
451 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">184.79 kg</td><td class="ddrTD">1210.28 m3</td><td class="ddrTD">734.83 kg/m3</td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
452 | + </tr> | ||
453 | + <tr class="ddrTR"> | ||
454 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1722.45 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
455 | + </tr> | ||
456 | + <tr class="ddrTR"> | ||
457 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">79.68 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
458 | + </tr> | ||
459 | + <tr class="ddrTR"> | ||
460 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1994.52 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
461 | + </tr> | ||
462 | + <tr class="ddrTR"> | ||
463 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">947.24 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
464 | + </tr> | ||
465 | + <tr class="ddrTR"> | ||
466 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1410.06 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
467 | + </tr> | ||
468 | + <tr class="ddrTR"> | ||
469 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1511.2 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
470 | + </tr> | ||
471 | + <tr class="ddrTR"> | ||
472 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">257.7 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
473 | + </tr> | ||
474 | + <tr class="ddrTR"> | ||
475 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1696.38 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
476 | + </tr> | ||
477 | + <tr class="ddrTR"> | ||
478 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">17.39 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
479 | + </tr> | ||
480 | + <tr class="ddrTR"> | ||
481 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">1718.14 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
482 | + </tr> | ||
483 | + <tr class="ddrTR"> | ||
484 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD"></td><td class="ddrTD">837.72 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
485 | + </tr> | ||
486 | + <tr class="ddrTR"> | ||
487 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">oil net</td><td class="ddrTD">431.35 kg</td><td class="ddrTD">934 m3</td><td class="ddrTD">748.01 kg/m3</td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD">net product flow</td> | ||
488 | + </tr> | ||
489 | + <tr class="ddrTR"> | ||
490 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">678.78 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
491 | + </tr> | ||
492 | + <tr class="ddrTR"> | ||
493 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1293.11 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
494 | + </tr> | ||
495 | + <tr class="ddrTR"> | ||
496 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">754.81 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
497 | + </tr> | ||
498 | + <tr class="ddrTR"> | ||
499 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">83.29 m3</td><td class="ddrTD"></td><td class="ddrTD">forecast flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
500 | + </tr> | ||
501 | + <tr class="ddrTR"> | ||
502 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1606 m3</td><td class="ddrTD"></td><td class="ddrTD">tariff basis flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
503 | + </tr> | ||
504 | + <tr class="ddrTR"> | ||
505 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">702 m3</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
506 | + </tr> | ||
507 | + <tr class="ddrTR"> | ||
508 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1898 m3</td><td class="ddrTD"></td><td class="ddrTD">nominated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
509 | + </tr> | ||
510 | + <tr class="ddrTR"> | ||
511 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">510.27 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
512 | + </tr> | ||
513 | + <tr class="ddrTR"> | ||
514 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">869.7 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
515 | + </tr> | ||
516 | + <tr class="ddrTR"> | ||
517 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">877.63 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
518 | + </tr> | ||
519 | + <tr class="ddrTR"> | ||
520 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">150.45 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
521 | + </tr> | ||
522 | + <tr class="ddrTR"> | ||
523 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">821.47 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
524 | + </tr> | ||
525 | + <tr class="ddrTR"> | ||
526 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1161.91 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
527 | + </tr> | ||
528 | + <tr class="ddrTR"> | ||
529 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1846.68 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
530 | + </tr> | ||
531 | + <tr class="ddrTR"> | ||
532 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">968.1 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
533 | + </tr> | ||
534 | + <tr class="ddrTR"> | ||
535 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1123.2 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
536 | + </tr> | ||
537 | + <tr class="ddrTR"> | ||
538 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1408.89 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
539 | + </tr> | ||
540 | + <tr class="ddrTR"> | ||
541 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">740.26 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
542 | + </tr> | ||
543 | + <tr class="ddrTR"> | ||
544 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">1817.69 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
545 | + </tr> | ||
546 | + <tr class="ddrTR"> | ||
547 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">608.86 m3</td><td class="ddrTD"></td><td class="ddrTD">budget flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
548 | + </tr> | ||
549 | + <tr class="ddrTR"> | ||
550 | + <td class="ddrTD">TRYM</td><td class="ddrTD">production exploitation</td><td class="ddrTD">water</td><td class="ddrTD"></td><td class="ddrTD">934 m3</td><td class="ddrTD"></td><td class="ddrTD">allocated flow</td><td class="ddrTD"></td><td class="ddrTD"></td> | ||
551 | + </tr> | ||
552 | + </table> | ||
553 | + <br> | ||
554 | + </div> | ||
555 | + <div> | ||
556 | + <hr> | ||
557 | + <h2>Production Inventory</h2> | ||
558 | + <table class="ddrTable"> | ||
559 | + <tr class="ddrTR"> | ||
560 | + <th class="ddrTH" style="text-align: center">Inventory Name</th><th class="ddrTH" style="text-align: center">Inventory Type</th><th class="ddrTH" style="text-align: center">Product</th><th class="ddrTH" style="text-align: center">Mass</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Density</th> | ||
561 | + </tr> | ||
562 | + <tr class="ddrTR"> | ||
563 | + <td class="ddrTD">Trym allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">432.8 kg</td><td class="ddrTD">1043.34 m3</td><td class="ddrTD">722.2 kg/m3</td> | ||
564 | + </tr> | ||
565 | + <tr class="ddrTR"> | ||
566 | + <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">785.22 kg</td><td class="ddrTD">759.39 m3</td><td class="ddrTD">758.11 kg/m3</td> | ||
567 | + </tr> | ||
568 | + </table> | ||
569 | + <br> | ||
570 | + </div> | ||
571 | + <div> | ||
572 | + <hr> | ||
573 | + <h2>Production Inventory Ownership</h2> | ||
574 | + <table class="ddrTable"> | ||
575 | + <tr class="ddrTR"> | ||
576 | + <th class="ddrTH" style="text-align: center">Inventory Name</th><th class="ddrTH" style="text-align: center">Inventory Type</th><th class="ddrTH" style="text-align: center">Product</th><th class="ddrTH" style="text-align: center">Volume</th><th class="ddrTH" style="text-align: center">Owner</th> | ||
577 | + </tr> | ||
578 | + <tr class="ddrTR"> | ||
579 | + <td class="ddrTD">Trym allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">575.61 m3</td><td class="ddrTD">Bayerngas Norge AS</td> | ||
580 | + </tr> | ||
581 | + <tr class="ddrTR"> | ||
582 | + <td class="ddrTD">Trym allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">467.73 m3</td><td class="ddrTD">DONG E&P Norge AS</td> | ||
583 | + </tr> | ||
584 | + <tr class="ddrTR"> | ||
585 | + <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">611.01 m3</td><td class="ddrTD">Bayerngas Norge AS</td> | ||
586 | + </tr> | ||
587 | + <tr class="ddrTR"> | ||
588 | + <td class="ddrTD">Fredericia allocated inventory volumes</td><td class="ddrTD"></td><td class="ddrTD">oil net</td><td class="ddrTD">148.38 m3</td><td class="ddrTD">DONG E&P Norge AS</td> | ||
589 | + </tr> | ||
590 | + </table> | ||
591 | + <br> | ||
592 | + </div> | ||
593 | + <div> | ||
594 | + <hr> | ||
595 | + <h2>Fluid Sample Report</h2> | ||
596 | + <table class="ddrTable"> | ||
597 | + <tr class="ddrTR"> | ||
598 | + <th class="ddrTH" style="text-align: center">Sample Type</th><th class="ddrTH" style="text-align: center">Aquisition Date</th><th class="ddrTH" style="text-align: center">Sampling Facility</th><th class="ddrTH" style="text-align: center">Fluid Sample Name</th> | ||
599 | + </tr> | ||
600 | + <tr class="ddrTR"> | ||
601 | + <td class="ddrTD">fluid sampling - separator gas</td><td class="ddrTD">2012-02-13</td><td class="ddrTD">TRYM</td><td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td> | ||
602 | + </tr> | ||
603 | + <tr class="ddrTR"> | ||
604 | + <td class="ddrTD">fluid sampling - separator oil</td><td class="ddrTD">2012-02-13</td><td class="ddrTD">TRYM</td><td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td> | ||
605 | + </tr> | ||
606 | + </table> | ||
607 | + <br> | ||
608 | + </div> | ||
609 | + <div> | ||
610 | + <hr> | ||
611 | + <h2>Fluid Sample Analysis Results</h2> | ||
612 | + <table class="ddrTable"> | ||
613 | + <tr class="ddrTR"> | ||
614 | + <th class="ddrTH" style="text-align: center">Fluid Sample Name</th><th class="ddrTH" style="text-align: center">Component</th><th class="ddrTH" style="text-align: center">Mole Ratio</th><th class="ddrTH" style="text-align: center">Mass Ratio</th><th class="ddrTH" style="text-align: center">Is Primary</th> | ||
615 | + </tr> | ||
616 | + <tr class="ddrTR"> | ||
617 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">isopentane</td><td class="ddrTD">6 %</td><td class="ddrTD">6 %</td><td class="ddrTD"></td> | ||
618 | + </tr> | ||
619 | + <tr class="ddrTR"> | ||
620 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">C1</td><td class="ddrTD">0.1 %</td><td class="ddrTD">0.1 %</td><td class="ddrTD"></td> | ||
621 | + </tr> | ||
622 | + <tr class="ddrTR"> | ||
623 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">N2</td><td class="ddrTD">1.9 %</td><td class="ddrTD">1.9 %</td><td class="ddrTD"></td> | ||
624 | + </tr> | ||
625 | + <tr class="ddrTR"> | ||
626 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">isobutane</td><td class="ddrTD">1.46 %</td><td class="ddrTD">1.46 %</td><td class="ddrTD"></td> | ||
627 | + </tr> | ||
628 | + <tr class="ddrTR"> | ||
629 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">CO2</td><td class="ddrTD">1 %</td><td class="ddrTD">1 %</td><td class="ddrTD"></td> | ||
630 | + </tr> | ||
631 | + <tr class="ddrTR"> | ||
632 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">propane</td><td class="ddrTD">0.64 %</td><td class="ddrTD">0.64 %</td><td class="ddrTD"></td> | ||
633 | + </tr> | ||
634 | + <tr class="ddrTR"> | ||
635 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">C6+</td><td class="ddrTD">2.5 %</td><td class="ddrTD">2.5 %</td><td class="ddrTD"></td> | ||
636 | + </tr> | ||
637 | + <tr class="ddrTR"> | ||
638 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">normal butane</td><td class="ddrTD">4 %</td><td class="ddrTD">4 %</td><td class="ddrTD"></td> | ||
639 | + </tr> | ||
640 | + <tr class="ddrTR"> | ||
641 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">ethane</td><td class="ddrTD">0.4 %</td><td class="ddrTD">0.4 %</td><td class="ddrTD"></td> | ||
642 | + </tr> | ||
643 | + <tr class="ddrTR"> | ||
644 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">normal pentane</td><td class="ddrTD">82 %</td><td class="ddrTD">82 %</td><td class="ddrTD"></td> | ||
645 | + </tr> | ||
646 | + <tr class="ddrTR"> | ||
647 | + <td class="ddrTD">TRYM-GAS-CHARACTERISTICS-1</td><td class="ddrTD">gas</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">True</td> | ||
648 | + </tr> | ||
649 | + <tr class="ddrTR"> | ||
650 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">ethane</td><td class="ddrTD">0.4 %</td><td class="ddrTD">0.4 %</td><td class="ddrTD"></td> | ||
651 | + </tr> | ||
652 | + <tr class="ddrTR"> | ||
653 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">C6+</td><td class="ddrTD">2.5 %</td><td class="ddrTD">2.5 %</td><td class="ddrTD"></td> | ||
654 | + </tr> | ||
655 | + <tr class="ddrTR"> | ||
656 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">C1</td><td class="ddrTD">0.1 %</td><td class="ddrTD">0.1 %</td><td class="ddrTD"></td> | ||
657 | + </tr> | ||
658 | + <tr class="ddrTR"> | ||
659 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">isopentane</td><td class="ddrTD">6 %</td><td class="ddrTD">6 %</td><td class="ddrTD"></td> | ||
660 | + </tr> | ||
661 | + <tr class="ddrTR"> | ||
662 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">propane</td><td class="ddrTD">0.64 %</td><td class="ddrTD">0.64 %</td><td class="ddrTD"></td> | ||
663 | + </tr> | ||
664 | + <tr class="ddrTR"> | ||
665 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">normal pentane</td><td class="ddrTD">82 %</td><td class="ddrTD">82 %</td><td class="ddrTD"></td> | ||
666 | + </tr> | ||
667 | + <tr class="ddrTR"> | ||
668 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">isobutane</td><td class="ddrTD">1.46 %</td><td class="ddrTD">1.46 %</td><td class="ddrTD"></td> | ||
669 | + </tr> | ||
670 | + <tr class="ddrTR"> | ||
671 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">normal butane</td><td class="ddrTD">4 %</td><td class="ddrTD">4 %</td><td class="ddrTD"></td> | ||
672 | + </tr> | ||
673 | + <tr class="ddrTR"> | ||
674 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">CO2</td><td class="ddrTD">1 %</td><td class="ddrTD">1 %</td><td class="ddrTD"></td> | ||
675 | + </tr> | ||
676 | + <tr class="ddrTR"> | ||
677 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">N2</td><td class="ddrTD">1.9 %</td><td class="ddrTD">1.9 %</td><td class="ddrTD"></td> | ||
678 | + </tr> | ||
679 | + <tr class="ddrTR"> | ||
680 | + <td class="ddrTD">TRYM-LIQUID-CHARACTERISTICS-1</td><td class="ddrTD">C7+</td><td class="ddrTD"></td><td class="ddrTD"></td><td class="ddrTD">True</td> | ||
681 | + </tr> | ||
682 | + </table> | ||
683 | + <br> | ||
684 | + </div> | ||
685 | + </body> | ||
686 | +</html> |
-
Please register or login to post a comment